Stimulus-response time to alarms of the intra-aortic balloon pump: safe care practices.

نویسندگان

  • Andrezza Serpa Franco
  • Adriana Carla Bridi
  • Monica de Almeida Karam
  • Ana Paula Amorim Moreira
  • Karla Biancha Silva de Andrade
  • Roberto Carlos Lyra da Silva
چکیده

OBJECTIVE To characterize the sound alarms of the Intra-Aortic Balloon Pump (IABP) during aortic counterpulsation therapy; to measure the stimulus-response time of the team to these; and to discuss the implications of increasing this time for patient safety from the alarm fatigue perspective. METHOD This is an observational and descriptive study with quantitative and qualitative approach, case study type, carried out in a Cardiac Surgical Intensive Care Unit. RESULTS The most audible IABP alarm was the one of high priority increased-reduced diastolic blood pressure. The stimulus-response time was 33.9 seconds on average. CONCLUSION Managing the alarms of these equipment is essential to minimize the occurrence of the alarm fatigue phenomenon and to offer a safer assistance to patients who rely on this technology.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Predictive Factors for Delayed Extubation in the Intensive Care Unit after Coronary Artery Bypass Grafting; A Southern Iranian Experience

Background: Early extubation is implemented in cardiothoracic units worldwide for its advantages such as decreased mortality, morbidity, and hospitalization costs. We conducted a retrospective study to evaluate potential factors which may affect extubation time. Methods: The records of 334 eligible patients who underwent elective coronary artery bypass grafting (CABG) in 2008 in Kowsar ...

متن کامل

Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...

متن کامل

False alarm rates of three third-generation pulse oximeters in PACU, ICU and IABP patients.

The objective of this clinical study was to determine alarm rates--in particular the frequency of false positive alarms--of three third-generation pulse oximeters in the postanesthesia care unit (PACU), the intensive care unit (ICU), and in patients with an intra-aortic balloon pump (IABP): Nellcor Symphony N-3000, a Masimo IVY 2000, and Agilent Viridia CMS 2000. All alarms were classified into...

متن کامل

Variables that predict reintubation after open-heart surgery

 Abstract Background: This study sought to determine patient characteristics, process of care, and outcome as predictors of reintubation after open-heart surgery. Methods: We performed a retrospective case control study that included all patients undergoing cardiac surgery who required reintubation and an equal number of control patients not requiring reintubation. Putative risk factors were an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Revista brasileira de enfermagem

دوره 70 6  شماره 

صفحات  -

تاریخ انتشار 2017