Adherence to acceptability and repeatability criteria for spirometry in complex lung function laboratories.

نویسندگان

  • Brigitte M Borg
  • M Faizel Hartley
  • Michael J Bailey
  • Bruce R Thompson
چکیده

BACKGROUND Few published data exist for adherence rates to spirometry acceptability and repeatability criteria in clinical respiratory laboratories. This study quantified adherence levels in this setting and observed changes in adherence levels as a result of feedback and ongoing training. METHODS Two tertiary hospital-based, lung function laboratories (L1 and L2) participated. Approximately 100 consecutive, FVC spirometry sessions were reviewed for each year from 2004 to 2008 at L1 and for years 2004 and 2008 at L2. Each spirometric effort and session was interrogated for adherence to the acceptability and repeatability criteria of international spirometry standards of the time. Feedback of audit results and refresher training were provided at L1 throughout the study; in addition, a quality rating scale was implemented in 2006. No formal feedback or follow-up training was provided at L2. RESULTS We reviewed 707 test sessions over the 5 years. There was no difference in adherence rates to acceptability and repeatability criteria between sites in 2004 (L1 61%, L2 59%, P = .89). There was, however, a significant difference between sites in 2008 (L1 92%, L2 65%, P < .001). No difference was seen at L2 between 2004 and 2008 (P = .26), while L1 experienced a significant increase in adherence levels between 2004 and 2008 (61% to 92% P < .001). CONCLUSIONS Clinical respiratory laboratories met published spirometry acceptability and repeatability criteria only 60% of the time in the first audit period. This improved with regular review, feedback, and implementation of a rating scale. Auditing of spirometry quality, feedback, and implementation of test rating scales need to be incorporated as an integral component of laboratory quality assurance programs to improve adherence to international acceptability and repeatability criteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spirometry training does not guarantee valid results.

BACKGROUND Many healthcare professionals performing spirometry in primary care have had less than half a day's training in spirometry practice, and the validity of the test results is questionable. Longer training periods, with or without follow-up training, may improve test validity. OBJECTIVE To determine if a 14-hour spirometry training course provides sufficient skill to produce valid res...

متن کامل

LUNOKID: can numerical American Thoracic Society/European Respiratory Society quality criteria replace visual inspection of spirometry?

The gold standard for assessing quality of forced expiratory manoeuvres is visual inspection by an expert. American Thoracic Society/European Respiratory Society numerical quality criteria (NQC) include back-extrapolated volume (BEV), repeatability and forced expiratory time (FET). Equipment currently available provides feedback tempting the investigator to use NQC as pass-fail criterion. To in...

متن کامل

Bronchodilator reversibility testing: laboratory practices in Australia and New Zealand.

OBJECTIVES To determine the variation in the methods used to assess and interpret the reversibility of airflow limitation in lung-function laboratories throughout Australia and New Zealand. DESIGN A postal survey performed in 2000, requesting details of methods used to assess and interpret bronchodilator reversibility. SETTING AND PARTICIPANTS 60 lung-function laboratories identified from t...

متن کامل

Characterization of pulmonary function in Duchenne Muscular Dystrophy

Decline in pulmonary function in Duchenne Muscular Dystrophy (DMD) contributes to significant morbidity and reduced longevity. Spirometry is a widely used and fairly easily performed technique to assess lung function, and in particular lung volume; however, the acceptability criteria from the American Thoracic Society (ATS) may be overly restrictive and inappropriate for patients with neuromusc...

متن کامل

The accuracy of FEF25-75/ FVC for primary classification of the pulmonary function test

Introduction: The forced expiratory flow at 25 and 75% of the pulmonary volume/forced vital capacity ratio (FEF25-75/FVC) as a spirometry parameter has been successful in the early diagnosis of chronic obstructive pulmonary disease (COPD) and the methacholine challenge test for assessing airway responsiveness.To determine the accuracy of FEF25-7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 57 12  شماره 

صفحات  -

تاریخ انتشار 2012