Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels.

نویسندگان

  • R Farré
  • M Ferrer
  • M Rotger
  • D Navajas
چکیده

Assessing respiratory impedance (Zrs) in ventilated patients over a wide frequency band, ranging from breathing rates to typical forced oscillation frequencies, during end-expiratory pauses at different positive end-expiratory pressures (PEEP) is of potential interest to assess a patient's respiratory mechanics. Zrs measurements under these conditions are not possible with the present variants of the forced oscillation technique. The aim of this work was to design a forced oscillation generator operating from spontaneous breathing frequencies whilst withstanding PEEP. To this end, we constructed a generator based on a servocontrolled loudspeaker. This allowed the loudspeaker cone to remain at its resting position regardless of the external PEEP applied. The system was optimized by using a mechanical analogue. The clinical applicability of the servocontrolled generator was assessed by measuring Zrs in mechanically-ventilated chronic obstructive pulmonary disease (COPD) patients during end-expiratory pauses at different transrespiratory pressures. The forced oscillation generator designed may be easily applicable in practice since it is small and light. The system is able to withstand transrespiratory pressures of up to 17 hPa and allows the application of forced oscillation of sufficient amplitude ( > 2 hPa peak-to-peak, 0.25-26 Hz) to obtain reliable respiratory resistance and reactance data. The servocontrolled generator permits the assessment of respiratory mechanics over a wide frequency band ranging from breathing frequencies to the most typical forced oscillation frequencies during end-expiratory pauses at PEEPs within the conventional range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-frequency assessment of airway and tissue mechanics in ventilated COPD patients.

Low-frequency forced oscillations have increasingly been employed to characterize airway and tissue mechanics separately in the normal respiratory system and animal models of lung disease; however, few data are available on the use of this method in chronic obstructive pulmonary disease (COPD). We studied 30 intubated and mechanically ventilated patients (COPD, n = 9; acute exacerbation of COPD...

متن کامل

Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial

INTRODUCTION Computed tomography of the lung has shown that ventilation shifts from dependent to nondependent lung regions. In this study, we investigated whether, at the bedside, electrical impedance tomography (EIT) at the cranial and caudal thoracic levels can be used to visualize changes in ventilation distribution during a decremental positive end-expiratory pressure (PEEP) trial and the r...

متن کامل

Respiratory mechanics in ventilated COPD patients: forced oscillation versus occlusion techniques.

The respiratory mechanics of artificially ventilated chronic obstructive pulmonary disease (COPD) patients were investigated by means of the forced oscillation (FOT) and the end-inspiratory airway occlusion (AOT) techniques. FOT was applied to measure respiratory resistance (Rrs) and reactance (Xrs) from 0.25-16 Hz. Maximum (Rmax) and minimum (Rmin) resistances, static elastance (Est) and time ...

متن کامل

Detection of ‘best’ positive end-expiratory pressure derived from electrical impedance tomography parameters during a decremental positive end-expiratory pressure trial

INTRODUCTION This study compares different parameters derived from electrical impedance tomography (EIT) data to define 'best' positive end-expiratory pressure (PEEP) during a decremental PEEP trial in mechanically-ventilated patients. 'Best' PEEP is regarded as minimal lung collapse and overdistention in order to prevent ventilator-induced lung injury. METHODS A decremental PEEP trial (from ...

متن کامل

Detection of optimal PEEP for equal distribution of tidal volume by volumetric capnography and electrical impedance tomography during decreasing levels of PEEP in post cardiac-surgery patients.

BACKGROUND Homogeneous ventilation is important for prevention of ventilator-induced lung injury. Electrical impedance tomography (EIT) has been used to identify optimal PEEP by detection of homogenous ventilation in non-dependent and dependent lung regions. We aimed to compare the ability of volumetric capnography and EIT in detecting homogenous ventilation between these lung regions. METHOD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 8 7  شماره 

صفحات  -

تاریخ انتشار 1995