CTPA protocol optimisation audit: challenges of dose reduction with maintained image quality.
نویسندگان
چکیده
AIM To assess computed tomography (CT) pulmonary angiography (CTPA) dose and image quality in a large teaching hospital, and subsequently, to optimise the protocol in order to reduce the dose without affecting image quality. MATERIALS AND METHODS Dose-length product (DLP), patient size, and objective quality parameters (contrast-to-noise ratio and signal-to-noise ratio on standardised levels) were recorded from 31 patients undergoing CTPA, where also a subjective image quality evaluation was carried out independently by three specialist cardiothoracic consultant radiologists. An equivalent objective and subjective quality assessment was carried out on a cohort of the same size in a different tertiary healthcare centre. Moreover, experimental tests using anthropomorphic chest phantoms were performed, using different scan parameters. In light of the above analysis, two of the scanner settings for CTPA were modified, i.e., the SureExposure pre-set was changed to "Standard" noise level, quantified with standard deviation (SD) of 19, and the minimum amperage setting lowered from 80 to 40 mA. A second cohort of patients using this new protocol was audited, following the same methodology. RESULTS The average DLP of patients undergoing CTPA was initially found to be higher than both local and national dose reference levels (DRLs; 559 versus 300 mGy·cm and 400 mGy·cm, respectively). The new protocol led to a reduction in average DLP (359 mGy·cm) while the image quality, assessed by three cardiothoracic consultant radiologists, was preserved. CONCLUSION The CTPA protocol was implemented in the Royal Infirmary of Edinburgh resulting in significant dose reduction, and is now compliant with national and local DRLs. The image quality was maintained.
منابع مشابه
Double-Low Dose Protocol of Computed Tomography Pulmonary Angiography (CTPA) in the Diagnosis of Pulmonary Embolism: A Feasible Approach for Reduction of Both Contrast Medium and Radiation Doses
This article discusses a hot topic on double low-dose protocol of computed tomography pulmonary angiography (CTPA) in the diagnosis of pulmonary embolism, with a special focus on a recent paper published in the British Journal of Radiology about the feasibility of this technique. Three aspects will be discussed in this review: First, both kVp and contrast medium can be reduced without affecting...
متن کاملOptimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملSubmillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging
OBJECTIVES To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. MATERIALS AND METHODS Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different prot...
متن کاملUltra Low Dose CT Pulmonary Angiography with Iterative Reconstruction
OBJECTIVE Evaluation of a new iterative reconstruction algorithm (IMR) for detection/rule-out of pulmonary embolism (PE) in ultra-low dose computed tomography pulmonary angiography (CTPA). METHODS Lower dose CT data sets were simulated based on CTPA examinations of 16 patients with pulmonary embolism (PE) with dose levels (DL) of 50%, 25%, 12.5%, 6.3% or 3.1% of the original tube current sett...
متن کاملAssessment of dose reduction and influence of gantry rotation time in CT abdomen examinations
Background: Worldwide the computed tomography (CT) scanning is recognized as a high radiation dose modality. This article aimed to estimate the radiation dose reduction and radiogenic risks for adult patients undertaking abdominal CT examinations. Materials and Methods: A total of 128 patients were studied using 2, 4, 16 and 64 slice CT scanners. The patients were divided into two categories: t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical radiology
دوره 73 3 شماره
صفحات -
تاریخ انتشار 2018