First evaluation of the Single Event Upset ( SEU ) risk for electronics in the CMS experiment
نویسندگان
چکیده
SEU error rates in the CMS tracker environment have been approximated with Monte Carlo simulations. The estimated upset rates for a submicron technology are 8.3 10-7 upsets/(bit s) at 4.9cm and 1.1 10-8 upsets/(bit s) at 49cm from the beam line, respectively. Comparison of simulation data with experimental proton irradiation benchmarks points to a tenfold underestimate of the actual rate. All these results have been obtained under the assumption of a 1Pm 3 sensitive volume and 1MeV energy threshold, and are very sensitive to the choice of these two parameters. The simulation indicates that mono-energetic proton beams are an effective tool for the SEU characterisation of ICs for the LHC radiation environment. Thermal neutrons might significantly contribute to the upset rate already in the outer parts of the tracker and in all the other parts of the experiment.
منابع مشابه
A New Method for Mitigation SEU Errors in Three-Dimensional FPGAs
Now a day's one of the most crucial issues in the field of FPGAGs, especially in SRAM FPGAs is single event upsets. One of the most effective methods to decrease these errors is using three dimensional FPGAs. This paper presents evaluation and mitigation of SEU cost on six layers three-dimensional (3D) FPGAs. The evaluation results show that SUE rate decrease about 67% on six layers 3D FPGAs. W...
متن کاملSingle Event Upset Studies on the APV6 Front End Readout Chip
The microstrip tracker for the CMS experiment at the LHC will be read out using radiation hard APV chips. During high luminosity running of the LHC the tracker will be exposed to particle fluxes up to 10 cm s. This high rate of particles introduces a concern that the APV could occasionally suffer from Single Event Upset (SEU). In order to evaluate the expected upset rate the APV was run under c...
متن کاملDynamic Partial based Single Event Upset (SEU) Injection Platform on FPGA
SRAM based FPGAs are attracting considerable interest especially in aerospace applications due to their high reconfigurability, low cost and availability. However, these devices are strongly susceptible to space radiation effects which are able to cause unwanted single event upsets (SEUs) in the configuration memory. In order to mitigate the SEU effects, various methods have been investigated i...
متن کاملIrradiation Test of the Altera Programmable Devices at the CMS Muon Endcap Clock and Control Board
The Clock and Control Board (CCB) [1] is the main interface unit between Timing, Trigger and Control (TTC) System [2] of the CMS Experiment and the Cathode Strip Chamber (CSC) EMU peripheral electronics [3]. The CCB (Fig.1) is a 9U*400 mm VME board which carries a TTCrx [2] card and a mezzanine card with the Altera EPF10K100 PLD [4] and EPC2 serial EPROM [5]. The TTCrx card is based on radiatio...
متن کاملRadiation test and application of FPGAs in the Atlas Level 1 Trigger
The use of SRAM based FPGA can provide the benefits of re-programmability, in system programming, low cost and fast design cycle. The single events upset (SEU) in the configuration SRAM due to radiation, change the design's function obliging the use in LHC environment only in the restricted area with low hadrons rate. Since we expect in the Atlas muon barrel an integrated dose of 300 Rads and 5...
متن کامل