Reducing the temperature sensitivity of SOI waveguide-based biosensors
نویسندگان
چکیده
Label-free photonic biosensors fabricated on silicon-on-insulator (SOI) can provide compact size, high evanescent field strength at the silicon waveguide surface, and volume fabrication potential. However, due to the large thermo optic coefficient of water-based biosamples, the sensors are temperature-sensitive. Consequently, active temperature control is usually used. However, for low cost applications, active temperature control is often not feasible. Here, we use the opposite polarity of the thermo-optic coefficients of silicon and water to demonstrate a photonic slot waveguide with a distribution of power between sample and silicon that aims to give athermal operation in water. Based on simulations, we made three waveguide designs close to the athermal point, and asymmetric integrated MachZehnder interferometers for their characterization. The devices were fabricated on SOI with a 220 nm device layer and 2 μm buried oxide, by electron beam lithography of hydrogen silsesquioxane (HSQ) resist, and etching in a Cl2/HBr/O2/He plasma. With Cargile 50350 fused silica matching oil as top cladding, the group index of the three guides varies from 1.9 to 2.8 at 1550 nm. The temperature sensitivity of the devices varied from –70 to –160 pm/K under the same conditions. A temperature sensitivity of –2 pm/K is projected with water as top cladding.
منابع مشابه
Enhanced Sensitivity of Absorption-Based Surface Plasmon Interference Sensors in Silicon-On-Insulator by Adsorbed Layer
We present an numerical investigation of a planar waveguide surface plasmon resonance (SPR) sensor in silicon-oninsulator (SOI) for detecting a change in the imaginary part of the refractive index. By adding a thin adsorbed layer between the metal-analyte boundary it is found that an enhanced sensitivity of the sensor is obtained, suggesting the possibility of realizing a highly integrated and ...
متن کاملHigh sensitivity waveguide grating sensor based on radiative losses.
A scheme of a waveguide sensor utilizing an output grating coupler with the grating length less than the coupling length is analyzed. This is the new method for the evaluation of average thickness of the adsorbed layer. This method, based on measurements of radiation loss coefficients, is proposed. Sensitivity limits of such a scheme are discussed. The new scheme has strong response on formatio...
متن کاملSilicon Nitride Bimodal Waveguides for High Sensitivity Biosensors
The fundamental properties of a bimodal waveguide interferometer were studied to evaluate its suitability for high sensitive biosensing applications. KeywordsBimodal waveguide, biosensors,, integrated optics, multimode waveguides, optical waveguides
متن کاملMach-Zehnder Interferometer Biochemical Sensor Based on Silicon-on-Insulator Rib Waveguide with Large Cross Section
A high-sensitivity Mach-Zehnder interferometer (MZI) biochemical sensing platform based on Silicon-in-insulator (SOI) rib waveguide with large cross section is proposed in this paper. Based on the analyses of the evanescent field intensity, the mode polarization and cross section dimensions of the SOI rib waveguide are optimized through finite difference method (FDM) simulation. To realize high...
متن کاملSensitivity Enhancement in Si Nanophotonic Waveguides Used for Refractive Index Sensing
A comparative study is given for the sensitivity of several typical Si nanophotonic waveguides, including SOI (silicon-on-insulator) nanowires, nanoslot waveguides, suspended Si nanowires, and nanofibers. The cases for gas sensing (ncl ~ 1.0) and liquid sensing (ncl ~ 1.33) are considered. When using SOI nanowires (with a SiO₂ buffer layer), the sensitivity for liquid sensing (S ~ 0.55) is high...
متن کامل