Monitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea.

نویسندگان

  • Oliver Senn
  • Christian F Clarenbach
  • Vladimir Kaplan
  • Marco Maggiorini
  • Konrad E Bloch
چکیده

OBJECTIVES The purpose of the study was to evaluate a novel, combined sensor for transcutaneous monitoring of arterial oxygen saturation and carbon dioxide tension. DESIGN The new monitoring technique was compared to established reference methods. SETTING ICU and sleep laboratory of a university hospital. PATIENTS Eighteen critically ill adult patients with acute respiratory failure or heart failure, and 12 patients with sleep apnea (mean [+/- SD] apnea/hypopnea index, 43 +/- 24 events per hour). MEASUREMENTS Continuous measurements were performed over several hours by the novel heated (temperature, 42 degrees C) earlobe sensor (TOSCA; Linde Medical Sensors; Basel, Switzerland), incorporating electrochemical and optical elements for carbon dioxide measurement (PtcCO2) and pulse oximetry (SpO2), respectively. The data were compared to the results of repeated arterial blood gas analyses in critically ill patients and to simultaneous nocturnal pulse oximetry performed with different devices with earlobe or finger sensors in sleep apnea patients. RESULTS In critically ill patients, the mean difference and limits of agreement (bias +/- 2 SDs) of transcutaneous PtcCO2 vs arterial PaCO2 were 3 +/- 7 mm Hg; the corresponding values for changes in PtcCO2 vs PaCO2 were 1 +/- 6 mm Hg. The bias +/- 2 SDs for pulse oximetric SpO2 vs arterial oxygen saturation (SaO2) were 1 +/- 4%. In sleep apnea patients, the combined earlobe sensor identified more transient oxygen desaturations, and the rate of change in oxygen saturation during events was greater compared to those with other tested pulse oximeters, indicating a faster response. CONCLUSIONS Due to its ability to accurately assess both ventilation and oxygenation by a single transcutaneous sensor, the described noninvasive monitoring technique is a valuable tool for respiratory monitoring with potential applications in critical care and sleep medicine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sleep hypoxia in myotonic dystrophy and its correlation with awake respiratory function.

BACKGROUND Tiredness and daytime respiratory failure occur frequently in myotonic dystrophy. Sleep hypoxaemia was studied in 12 patients with myotonic dystrophy and correlations were sought with their daytime lung and respiratory muscle function. METHODS All patients underwent overnight sleep studies, clinical assessment, measurement of flow-volume loops and carbon monoxide transfer factor, a...

متن کامل

Effects of protriptyline on sleep related disturbances of breathing in restrictive chest wall disease.

The effects of protriptyline on sleep stage distribution and gas exchange have been assessed in eight patients with nocturnal hypoventilation secondary to restrictive chest wall disease. At a dose of 10-20 mg taken when they retired the total sleeping time was unaltered but the proportion of rapid eye movement (REM) sleep fell from 22% to 12% (p less than 0.05). The total time spent at an arter...

متن کامل

Respiration during sleep in kyphoscoliosis.

Eleven subjects with non-paralytic and 10 with paralytic kyphoscoliosis and nine normal control subjects were studied during sleep. The Cobb angle of those with kyphoscoliosis varied from 60 degrees to 140 degrees (median 100 degrees) and the vital capacity varied from 17% to 56% (median 28%) of the value predicted on the basis of span. Recordings made during sleep included expired carbon dioxi...

متن کامل

Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip.

BACKGROUND We compared the accuracy and practicability of a new combined ear sensor device measuring pulse oximetry and transcutaneous carbon dioxide tension. METHODS Validation studies were done by comparing the results of the combined sensor with arterial blood gas measurements. In an observational part, monitoring data were obtained from 25 patients undergoing colonoscopy, sedated with mid...

متن کامل

Disordered breathing during sleep and exercise in idiopathic pulmonary fibrosis and the role of biomarkers.

BACKGROUND AND OBJECTIVE Idiopathic pulmonary fibrosis (IPF) patients report fatigue, possibly reflecting sleep disturbance, but little is known about sleep-related changes. We compared ventilation and gas exchange during sleep and exercise in a cohort of IPF patients, and evaluated associations with selected biological markers. METHODS Twenty stable IPF patients (aged 67.9 ± 12.3 [SD]) under...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 128 3  شماره 

صفحات  -

تاریخ انتشار 2005