It is well known that increased surface roughness of SF6 insulated electrode arrangements is significantly lowering the breakdown voltage [1], [2]. This effect becomes stronger with rising pressure and homogeneity of the electrodes. Since each breakdown changes the surface condition of the electrodes, it becomes very ambitious to measure breakdown probabilities in a statistical meaningful way. To cope with this difficulty a surface tracking device was introduced, consisting of a photo camera and image processing software. This device aids to decrease statistical dependencies through post processing of the measured data after an experiment.
منابع مشابه
SF6 High Voltage Circuit Breaker Contact Systems Under Lightning Impulse and Very Fast Transient Voltage Stress
In the past few years gas insulated high voltage circuit breakers have improved considerably, in particular with respect to required drive energy for operation, compactness and reliability. A further reduction in size implies increasing operational field stress inside the breaker and, thus, a reduction in built-in safety margins. If the design comes closer to its physical limits, in particular ...
متن کاملDielectric Strength of Different Gases in GIS
SF6 is a gas with excellent dielectric properties and is commonly used in gas-insulated equipment. However it has the high global warming potential. Thus, the development of new gases or gas mixtures for GIS, GIL is strongly desired. For dimensioning the gas insulated systems the support insulators (spacers) are of special interest. Contaminations on the insulator surface can cause field distor...
متن کاملUsing SF6 Decomposed Component Analysis for the Diagnosis of Partial Discharge Severity Initiated by Free Metal Particle Defect
The decomposition characteristics of a SF6 gas-insulated medium were used to diagnose the partial discharge (PD) severity in DC gas-insulated equipment (DC-GIE). First, the PD characteristics of the whole process were studied from the initial PD to the breakdown initiated by a free metal particle defect. The average discharge magnitude in a second was used to characterize the PD severity and th...
متن کاملEffect of Lightning Impulse Voltage on the Performance of 1-phase Gas Insulated Busduct in the Presence of Metallic Particle Contamination with Sf6/n2 Gas Mixtures
SF6 is the main mode of insulation in a GIS. However, in recent years, the future use of SF6 has been debated throughout the world in spite of it having all the desirable properties of a good insulating and arc quenching medium. Sulfur hexafluoride (SF6) has been used as a gaseous dielectric (insulator) in high voltage equipment since the 1950s. It is now known that SF6 is a potent greenhouse w...
متن کاملRole of Ion Sources for Spacer Charging in SF6 Gas Insulated HVDC Systems
Stationary DC electric fields are determined by the resistivity distribution of the insulation materials. In the presence of interfaces between different insulation materials, charge accumulation at these boundary layers may have a significant influence on the electric field distribution and with it on the breakdown strength of the arrangement. In many previous works, surface charging of model ...