Source localization in EEG represents a high dimensional inverse problem, which is severely ill-posed by nature. Fortunately, sparsity constraints have come into rescue as it helps solving the ill-posed problems when the signal is sparse. When the signal has a structure such as block structure, consideration of block sparsity produces better results. Knowing sparse Bayesian learning is an important member in the family of sparse recovery, and a superior choice when the projection matrix is highly coherent (which is typical the case for EEG), in this work we evaluate the performance of block sparse Bayesian learning (BSBL) method for EEG source localization. It is already accepted by the EEG community that a group of dipoles rather than a single dipole are activated during brain activities; thus, block structure is a reasonable choice for EEG. In this work we use two definitions of blocks: Brodmann areas and automated anatomical labelling (AAL), and analyze the reconstruction performance of BSBL methodology for them. A realistic head model is used for the experiment, which was obtained from segmentation of MRI images. When the number of simultaneously active blocks is 2, the BSBL produces overall localization accuracy of less than 5 mm without the presence of noise. The presence of more than 3 simultaneously active blocks and noise significantly affect the localization performance. Consideration of AAL based blocks results more accurate source localization in comparison to Brodmann area based blocks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Head Model Simplification on Beamformer Source Localization

Beamformers are a widely-used tool in brain analysis with magnetoencephalography (MEG) and electroencephalography (EEG). For the construction of the beamformer filters realistic head volume conductor modeling is necessary for accurately computing the EEG and MEG leadfields, i.e., for solving the EEG and MEG forward problem. In this work, we investigate the influence of including realistic head ...

متن کامل

Combination of Beamforming and Synchronization Methods for Epileptic Source Localization, using Simulated EEG Signals

Localization of sources in patients with focal seizure has recently attracted many attentions. In the severe cases of focal seizure, there is a possibility of doing neurosurgery operation to remove the defected tissue. The prosperity of this heavy operation completely depends on the accuracy of source localization. To increase this accuracy, this paper presents a new weighted beamforming method...

متن کامل

Sparse Bayesian Learning for EEG Source Localization

Purpose: Localizing the sources of electrical activity from electroencephalographic (EEG) data has gained considerable attention over the last few years. In this paper, we propose an innovative source localization method for EEG, based on Sparse Bayesian Learning (SBL). Methods: To better specify the sparsity profile and to ensure efficient source localization, the proposed approach considers g...

متن کامل

A Comparison of LORETA and the Borgiotti-Kaplan Beamformer in Simulated EEG Source Localization with a Realistic Head Model

An accurate and robust EEG source localization algorithm is an asset in the understanding, diagnosis, and treatment of some neurological disorders. Two inverse algorithms, LORETA and the Borgiotti-Kaplan beamformer (BK Beam) are used to localize a single dipole source from a simulated EEG within a realistic head model. Compared over a range of SNR values and source locations, the BK Beam exhibi...

متن کامل

Monte Carlo simulation studies of EEG and MEG localization accuracy.

Both electroencephalography (EEG) and magnetoencephalography (MEG) are currently used to localize brain activity. The accuracy of source localization depends on numerous factors, including the specific inverse approach and source model, fundamental differences in EEG and MEG data, and the accuracy of the volume conductor model of the head (i.e., the forward model). Using Monte Carlo simulations...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Int. J. Imaging Systems and Technology

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2017