Dosimetric comparison of various optimization techniques for high dose rate brachytherapy of interstitial cervix implants

نویسندگان

  • Bondel Shwetha
  • Manickam Ravikumar
  • Aradhana Katke
  • Sanjay S. Supe
  • Golhalli VenkataGiri
  • Nanda Ramanand
  • Tanvir Pasha
چکیده

HDR brachytherapy treatment planning often involves optimization methods to calculate the dwell times and dwell positions of the radioactive source along specified afterloading catheters. The purpose of this study is to compare the dose distribution obtained with geometric optimization (GO) and volume optimization (VO) combined with isodose reshaping. This is a retrospective study of 10 cervix HDR interstitial brachytherapy implants planned using geometric optimization and treated with a dose of 6 Gy per fraction. Four treatment optimization plans were compared: geometric optimization (GO), volume optimization (VO), geometric optimization followed by isodose reshape (GO_IsoR), and volume optimization followed by isodose reshape (VO_IsoR). Dose volume histogram (DVH) was analyzed and the four plans were evaluated based on the dosimetric parameters: target coverage (V100), conformal index (COIN), homogeneity index (HI), dose nonuniformity ratio (DNR) and natural dose ratio (NDR). Good target coverage by the prescription dose was achieved with GO_ IsoR (mean V100 of 88.11%), with 150% and 200% of the target volume receiving 32.0% and 10.4% of prescription dose, respectively. Slightly lower target coverage was achieved with VO_IsoR plans (mean V100 of 86.11%) with a significant reduction in the tumor volume receiving high dose (mean V150 of 28.29% and mean V200 of 7.3%). Conformity and homogeneity were good with VO_ IsoR (mean COIN = 0.75 and mean HI = 0.58) as compared to the other optimization techniques. VO_IsoR plans are superior in sparing the normal structures while also providing better conformity and homogeneity to the target. Clinically acceptable plans can be obtained by isodose reshaping provided the isodose lines are dragged carefully.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

Treatment Planning Methods in High Dose Rate Interstitial Brachytherapy of Carcinoma Cervix: A Dosimetric and Radiobiological Analysis

Treatment planning is a trial and error process that determines optimal dwell times, dose distribution, and loading pattern for high dose rate brachytherapy. Planning systems offer a number of dose calculation methods to either normalize or optimize the radiation dose. Each method has its own characteristics for achieving therapeutic dose to mitigate cancer growth without harming contiguous nor...

متن کامل

Study of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis

Background: This study evaluates dosimetric and spatial variations in inter–fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...

متن کامل

A patient‐based dosimetric study of intracavitary and interstitial brachytherapy in advanced stage carcinoma of the cervix

Intracavitary brachytherapy (ICBT) and interstitial brachytherapy (IB) techniques are commonly practiced for treating carcinoma of the cervix, either alone or in combination with external beam radiotherapy. Both these brachytherapy techniques have their own advantages and limitations in terms of tumor coverage and normal tissue sparing. Limited studies have been reported comparing the dosimetri...

متن کامل

A detailed dosimetric comparison between manual and inverse plans in HDR intracavitary/interstitial cervical cancer brachytherapy

PURPOSE The purpose of this study was to compare two inverse planning algorithms for cervical cancer brachytherapy and a conventional manual treatment planning according to the MUW (Medical University of Vienna) protocol. MATERIAL AND METHODS For 20 patients, manually optimized, and, inversely optimized treatment plans with Hybrid Inverse treatment Planning and Optimization (HIPO) and with In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -