The integrated exposure uptake biokinetic model for lead in children: independent validation and verification.
نویسندگان
چکیده
The U.S. Environmental Protection Agency employs a model, the integrated exposure biokinetic (IEUBK) model for lead in children, for the assessment of risks to children posed by environmental lead at hazardous waste sites. This paper describes results of an effort to verify the consistency of the documentation with the computer model and to test the computer code using a group that is independent from those involved in the model development. This review concluded that the IEUBK model correctly calculates the equations specified in the IEUBK model theory documentation. However, several issues were identified on model documentation, model performance, and the C++ programming language code (i.e., IEUBK model source code) documentation. These issues affect the ability of an independent reviewer to understand the workings of the IEUBK model but not the model's reliability. As a result of these findings, recommendations have been provided for updating documentation to the model as well as associated adjustments to the model documentation.
منابع مشابه
Integrated exposure uptake biokinetic model for lead in children: empirical comparisons with epidemiologic data.
The concept of model validation is evolving in the scientific community. This paper addresses the comparison of observed and predicted estimates as one component of model validation as applied to the integrated exposure uptake biokinetic (IEUBK) model for lead in children. The IEUBK model is an exposure (dose)-response model that uses children's environmental lead exposures to estimate risk of ...
متن کاملThe conceptual structure of the integrated exposure uptake biokinetic model for lead in children.
The integrated exposure uptake biokinetic model for lead in children was developed to provide plausible blood lead distributions corresponding to particular combinations of multimedia lead exposure. The model is based on a set of equations that convert lead exposure (expressed as micrograms per day) to blood lead concentration (expressed as micrograms per deciliter) by quantitatively mimicking ...
متن کاملCalculating the interindividual geometric standard deviation for use in the integrated exposure uptake biokinetic model for lead in children.
The integrated exposure uptake biokinetic (IEUBK) model, recommended for use by the U.S. Environmental Protection Agency at residential Superfund sites to predict potential risks to children from lead exposure and to establish lead remediation levels, requires an interindividual geometric standard deviation (GSDi) as an essential input parameter. The GSDi quantifies the variability of blood lea...
متن کاملMeasurement error, biases, and the validation of complex models for blood lead levels in children.
Measurement error causes biases in regression fits. If one could accurately measure exposure to environmental lead media, the line obtained would differ in important ways from the line obtained when one measures exposure with error. The effects of measurement error vary from study to study. It is dangerous to take measurement error corrections derived from one study and apply them to data from ...
متن کاملStructure, use, and validation of the IEUBK model.
The potential impact of the effects of lead in children is a major concern. Although measurements of lead concentration can be made in a geographic area, it is difficult to predict the effects of this exposure that involve complicated biologic functions. Dynamic mathematical models that can be simulated on a digital computer provide one method of analysis to facilitate the prediction process. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental Health Perspectives
دوره 106 شماره
صفحات -
تاریخ انتشار 1998