Asthma and the indoor environment: the significance of emission of formaldehyde and volatile organic compounds from newly painted indoor surfaces.

نویسندگان

  • G Wieslander
  • D Norbäck
  • E Björnsson
  • C Janson
  • G Boman
چکیده

As a part of the worldwide European Community Respiratory Health Survey, possible relations between asthma and emissions from newly painted indoor surfaces were studied. The participants (n = 562) answered a self-administered questionnaire, with questions on symptoms and indoor exposures, including indoor painting, during the last 12 months. The participants also underwent a structured interview, spirometry, peak flow measurements at home (PEF), methacholine provocation test for bronchial hyper-responsiveness (BHR), and skin prick tests. In addition, serum concentration of eosinophilic cationic protein (S-ECP), blood eosinophil count (B-EOS), and total immunoglobulin E (S-IgE) were measured. Current asthma was defined as a combination of BHR and at least one asthma-related symptom (wheezing and attacks of breathlessness). The information gathered on indoor painting was compared with exposure measurements of formaldehyde and volatile organic compounds (VOC) performed in a selected sample of the dwellings (n = 62). Relations between exposures, asthma and clinical signs were calculated by multiple linear or logistic regression, adjusting for possible influence of age, gender and tobacco smoking. The prevalence of asthma was increased among subjects with domestic exposure to newly painted surfaces (OR = 1.5; 95% CI 1.0-2.4), particularly newly painted wood details (OR = 2.3; 95% CI 1.2-4.5) and kitchen painting (OR = 2.2; 95% CI 1.1-4.5). Moreover, blood eosinophil concentrations were significantly elevated among subjects living in newly painted dwellings. A significantly increased prevalence of symptoms related to asthma, but not BHR, was observed in relation to workplace exposure to newly painted surfaces. The indoor concentration of aliphatic compounds (C8-C11), butanols, and 2,2,4-trimethyl 1,3-pentanediol diisobutyrate (TXIB) was significantly elevated in newly painted dwellings. The total indoor VOC was about 100 micrograms/m3 higher in dwellings painted in the last year. A significant increase in formaldehyde concentration was observed in dwellings with newly painted wood details. Our results indicate that exposure to chemical emissions from indoor paint is related to asthma, and that some VOCs may cause inflammatory reactions in the airways. To improve asthma management, and to counteract the increasing frequency of asthma, the significance of the indoor environment should not be neglected. Our study suggests that the contribution of emissions from paint to indoor concentrations of formaldehyde and VOCs should be as low as possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of VOCs, PM10, and Formaldehyde Exposure in the Hair Salons of South Korea

Introduction: In hair salons, workers and customers are exposed to high concentrations of several chemical compounds used during the working environment. Volatile Organic Compounds (VOCs), particulate matter (PM10), nitrogen dioxide (NO2), sulfur dioxide (SO2), carbon monoxide (CO), and formaldehyde are the major chemicals that alter the indoor air quality. This study aimed to assess the indoor...

متن کامل

Asthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings.

OBJECTIVES As a part of the worldwide European Community respiratory health survey, possible relations between symptoms of asthma, building characteristics, and indoor concentration of volatile organic compounds (VOCs) in dwellings were studied. METHODS The study comprised 88 subjects, aged 20-45 years, from the general population in Uppsala, a mid-Swedish urban community, selected by stratif...

متن کامل

Formaldehyde and volatile organic compounds in Hong Kong homes: concentrations and impact factors.

UNLABELLED This paper presents formaldehyde and volatile organic compounds (VOC) concentrations, potential sources and impact factors in 100 homes. The 24-h average formaldehyde concentration in 37 homes exceeded the good class of the Hong Kong Indoor Air Quality Objectives (HKIAQO), whereas the total VOCs concentration in all homes was lower than the HKIAQO. Compared to other East Asian cities...

متن کامل

Removal of Indoor Volatile Organic Compounds

Volatile organic compounds (VOCs) and formaldehyde are ubiquitous in indoor environment. 16 Inhalation of VOCs can cause irritations, difficulty breathing, and nausea, and damage the central 17 nervous system as well as other organs. Formaldehyde is even a carcinogen. Removal of VOCs and 18 formaldehyde is thus critical to control indoor air quality (IAQ). Photocatalytic oxidation has been 19 d...

متن کامل

Source Apportionment Of High Reactive Volatile Organic Compounds In a Region With The Massive Hydrocarbon Processing Industries

In the Persian Gulf region, conditions are highly favorable for ozone air pollution and the region is a hot spot of photochemical smog. The vast activities in processing oil and gas play a major role in it. It was found that the elevated concentrations of reactive hydrocarbons co-emitted with nitrogen oxides from Hydrocarbon Processing facilities lead to substantial ozone production. South Pars...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International archives of occupational and environmental health

دوره 69 2  شماره 

صفحات  -