Single-shot soft x-ray laser linewidth measurement using a grating interferometer.
نویسندگان
چکیده
The linewidth of a 14.7 nm wavelength Ni-like Pd soft x-ray laser was measured in a single shot using a soft x-ray diffraction grating interferometer. The instrument uses the time delay introduced by the gratings across the beam to measure the temporal coherence. The spectral linewidth of the 4d1S0-4p1P1 Ni-like Pd lasing line was measured to be Δλ/λ=3×10(-5) from the Fourier transform of the fringe visibility. This single shot linewidth measurement technique provides a rapid and accurate way to determine the temporal coherence of soft x-ray lasers that can contribute to the development of femtosecond plasma-based soft x-ray lasers.
منابع مشابه
Soft-x-ray interferometer for single-shot laser linewidth measurements.
A soft-x-ray Mach-Zehnder interferometer configuration that makes use of the time delay introduced by diffraction gratings to conduct single-shot measurements of the linewidth of soft-x-ray laser amplifiers is proposed and analyzed. The scheme was experimentally demonstrated in the near-IR region of the spectrum by measurement of the mode separation of a semiconductor laser. A symmetric configu...
متن کاملLinewidth and frequency jitter measurement of an erbium-doped fiber ring laser by using a loss-compensated, delayed self-heterodyne interferometer.
The single-mode linewidth of an erbium-doped, single-frequency, fiber ring laser has been measured by using a newly developed loss-compensated delayed self-heterodyne interferometer that has a resolution of less than 600 Hz. The natural linewidth is determined to have an upper bound of less than 2 kHz. In addition, frequency jitter was found to be dominant over the natural mately 4 kHz.
متن کاملTemporal coherence and spectral linewidth of an injection-seeded transient collisional soft x-ray laser.
The temporal coherence of an injection-seeded transient 18.9 nm molybdenum soft x-ray laser was measured using a wavefront division interferometer and compared to model simulations. The seeded laser is found to have a coherence time similar to that of the unseeded amplifier, ~1 ps, but a significantly larger degree of temporal coherence. The measured coherence time for the unseeded amplifier is...
متن کاملElectromagnetic-field distribution measurements in the soft x-ray range: full characterization of a soft x-ray laser beam.
We report direct measurement of the electromagnetic-field spatial distribution in a neonlike Ar capillary discharge-driven soft x-ray laser beam. The wave front was fully characterized in a single shot using a Shack-Hartmann diffractive optics sensor. The wave front was observed to be dependent on the discharge pressure and capillary length, as a result of beam refraction variations in the capi...
متن کاملA single-shot line-scanning spatially dispersed short coherence interferometer using Fourier transform profilometry
Single-shot inspection at nanoscale resolution is a problematic challenge for providing on-line inspection of manufacturing techniques such as roll-to-roll processes where the measurand is constantly moving. An example of such a measurement challenge is defect detection on vapor barrier films formed by depositing an aluminum oxide layer several tens of nanometres thick on a flexible polymer sub...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 38 23 شماره
صفحات -
تاریخ انتشار 2013