A Linear Relationship between Crystal Size and Fragment Binding Time Observed Crystallographically: Implications for Fragment Library Screening Using Acoustic Droplet Ejection
نویسندگان
چکیده
High throughput screening technologies such as acoustic droplet ejection (ADE) greatly increase the rate at which X-ray diffraction data can be acquired from crystals. One promising high throughput screening application of ADE is to rapidly combine protein crystals with fragment libraries. In this approach, each fragment soaks into a protein crystal either directly on data collection media or on a moving conveyor belt which then delivers the crystals to the X-ray beam. By simultaneously handling multiple crystals combined with fragment specimens, these techniques relax the automounter duty-cycle bottleneck that currently prevents optimal exploitation of third generation synchrotrons. Two factors limit the speed and scope of projects that are suitable for fragment screening using techniques such as ADE. Firstly, in applications where the high throughput screening apparatus is located inside the X-ray station (such as the conveyor belt system described above), the speed of data acquisition is limited by the time required for each fragment to soak into its protein crystal. Secondly, in applications where crystals are combined with fragments directly on data acquisition media (including both of the ADE methods described above), the maximum time that fragments have to soak into crystals is limited by evaporative dehydration of the protein crystals during the fragment soak. Here we demonstrate that both of these problems can be minimized by using small crystals, because the soak time required for a fragment hit to attain high occupancy depends approximately linearly on crystal size.
منابع مشابه
Hitting the target: fragment screening with acoustic in situ co-crystallization of proteins plus fragment libraries on pin-mounted data-collection micromeshes
Acoustic droplet ejection (ADE) is a powerful technology that supports crystallographic applications such as growing, improving and manipulating protein crystals. A fragment-screening strategy is described that uses ADE to co-crystallize proteins with fragment libraries directly on MiTeGen MicroMeshes. Co-crystallization trials can be prepared rapidly and economically. The high speed of specime...
متن کاملAcoustic transfer of protein crystals from agarose pedestals to micromeshes for high-throughput screening
Acoustic droplet ejection (ADE) is an emerging technology with broad applications in serial crystallography such as growing, improving and manipulating protein crystals. One application of this technology is to gently transfer crystals onto MiTeGen micromeshes with minimal solvent. Once mounted on a micromesh, each crystal can be combined with different chemicals such as crystal-improving addit...
متن کاملDetermination of equilibrium dissociation constants for recombinant antibodies by high-throughput affinity electrophoresis
High-quality immunoreagents enhance the performance and reproducibility of immunoassays and, in turn, the quality of both biological and clinical measurements. High quality recombinant immunoreagents are generated using antibody-phage display. One metric of antibody quality - the binding affinity - is quantified through the dissociation constant (KD) of each recombinant antibody and the target ...
متن کاملConstruction of a human recombinant polyclonal Fab fragment antibody library using peripheral blood lymphocytes of snake bitten victims
Human snake bitten poisoning is a serious threat in many tropical and subtropical countries such as Iran. The best acceptable treatment of envenomated humans is antivenoms; however they have a series of economic and medical problems and need more improvements. In this study a combinatorial human immunoglobulin gene library against some of Iranian snakes venoms was constructed. Total RNA prepare...
متن کاملLibrary design for fragment based screening.
According to Hann's model of molecular complexity an increased probability of detection binding to a target protein can be expected when small, low complex molecular fragments are screened with high sensitivity instead of full-sized ligands with lower sensitivity. Analysis of the HTS summary data of Novartis and comparison with NMR screening results obtained on generic fragment libraries indica...
متن کامل