The "White Gray Sign" Identifies the Central Sulcus on 3T High-Resolution T1-Weighted Images.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The central sulcus is an important anatomic landmark, but most methods of identifying it rely on variable gyral and sulcal patterns. We describe and assess the accuracy of reduced gray-white contrast along the central sulcus, an observation we term the "white gray sign." MATERIALS AND METHODS We conducted a retrospective review of 51 fMRIs with a T1-weighted 3D inversion recovery fast-spoiled gradient-echo and concomitant hand-motor fMRI, which served as confirmation for the location of the central sulcus. To measure gray-white contrast across the central and adjacent sulci, we performed a quantitative analysis of 25 normal hemispheres along the anterior and posterior cortices and intervening white matter of the pre- and postcentral gyri. 3D inversion recovery fast-spoiled gradient-echo axial images from 51 fMRIs were then evaluated by 2 raters for the presence of the white gray sign as well as additional established signs of the central sulcus: the bracket, cortical thickness, omega, and T signs. RESULTS The mean gray-white contrast along the central sulcus was 0.218 anteriorly and 0.237 posteriorly, compared with 0.320 and 0.295 along the posterior precentral and anterior postcentral sulci, respectively (P < .001). Both raters correctly identified the central sulcus in all 35 normal and 16 abnormal hemispheres. The white gray sign had the highest agreement of all signs between raters and was rated as present the most often among all the signs. CONCLUSIONS Reduced gray-white contrast around the central sulcus is a reliable sign for identification of the central sulcus on 3D inversion recovery fast-spoiled gradient-echo images.
منابع مشابه
Enhancing gray-to-white matter contrast in 3T T1 spin-echo brain scans by optimizing flip angle.
BACKGROUND AND PURPOSE Compared with MR imaging at 1.5T T1-weighted spin-echo imaging at 3T shows up with reduced gray-to-white matter contrast. The purpose of the present study was to show the effects of alterations of different flip angles as an easily accessible parameter to increase gray-to-white matter contrast. METHODS Spin-echo T1 sequences of 6 healthy volunteers were acquired in a 3T...
متن کاملFully automatic detection of deep white matter T1 hypointense lesions in multiple sclerosis.
A novel method is presented for fully automatic detection of candidate white matter (WM) T1 hypointense lesions in three-dimensional high-resolution T1-weighted magnetic resonance (MR) images. By definition, T1 hypointense lesions have similar intensity as gray matter (GM) and thus appear darker than surrounding normal WM in T1-weighted images. The novel method uses a standard classification al...
متن کاملNon-rigid Registration of T1 MR Images Constrained with Fractional Anisotropic (FA) Maps
Introduction Conventional images, such as T1 weighted (T1W) or T2 weighted (T2W) MR images, provide basic contrast information between gray matter, white matter, and cerebro-spinal fluid. However, those images are limited because they provide little contrast between distinct white matter structures. Diffusion tensor imaging (DTI) is a complementary tool that provides information on the orientat...
متن کاملThalamic nuclei segmentation in clinical 3T T1-weighted Images using high-resolution 7T shape models
Accurate and reliable identification of thalamic nuclei is important for surgical interventions and neuroanatomical studies. This is a challenging task due to their small sizes and low intra-thalamic contrast in standard T1-weighted or T2weighted images. Previously proposed techniques rely on diffusion imaging or functional imaging. These require additional scanning and suffer from the low reso...
متن کاملNeurobiological origin of spurious brain morphological changes: A quantitative MRI study
The high gray-white matter contrast and spatial resolution provided by T1-weighted magnetic resonance imaging (MRI) has made it a widely used imaging protocol for computational anatomy studies of the brain. While the image intensity in T1-weighted images is predominantly driven by T1, other MRI parameters affect the image contrast, and hence brain morphological measures derived from the data. B...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 38 2 شماره
صفحات -
تاریخ انتشار 2017