Double-tilt electron tomography.

نویسندگان

  • P Penczek
  • M Marko
  • K Buttle
  • J Frank
چکیده

Fidelity of tomographic reconstructions is improved and reconstruction artifacts are reduced, without increasing the number of projections, by combining tilt series taken around two orthogonal axes. Test reconstructions were made from high-voltage EM of rat liver mitochondria in a 0.6 micron thick plastic section. A number of schemes for selecting tilt angles for the projections are compared. A new method for aligning fiducial markers is described. It uses an iterative algorithm to determine the shift, scale, in-plane rotation and tilt angle for each tilt image, enforcing agreement of the expected locations of the fiducial markers in 3D space. These 3D locations are used to find the orientation between two tilt series and to merge both sets of projections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conical Tomography: A Method for the Study of Macromolecular Assemblies

We have developed conical tomography for the transmission electron microscope to study a wide range of structures at molecular resolution. Unlike the other related types of tomography (single and double-axis tilt), conical tomography has a higher throughput and more importantly, produces reconstructions that are isotropic in the x-y plane with a resolution of 2-3nm [1]. Using a custom made tilt...

متن کامل

3D reconstruction of biological structures: automated procedures for alignment and reconstruction of multiple tilt series in electron tomography

Transmission electron microscopy allows the collection of multiple views of specimens and their computerized three-dimensional reconstruction and analysis with electron tomography. Here we describe development of methods for automated multi-tilt data acquisition, tilt-series processing, and alignment which allow assembly of electron tomographic data from a greater number of tilt series, yieldin...

متن کامل

Rapid low dose electron tomography using a direct electron detection camera

We demonstrate the ability to record a tomographic tilt series containing 3487 images in only 3.5 s by using a direct electron detector in a transmission electron microscope. The electron dose is lower by at least one order of magnitude when compared with that used to record a conventional tilt series of fewer than 100 images in 15-60 minutes and the overall signal-to-noise ratio is greater tha...

متن کامل

3d Transmission Electron Microscopy of Biological Nanomachines

Nature of the specimen: Depending on the nature of each sample, different strategies must be chosen. Thus, if the sample contains a single object, electron tomography should be chosen. This is the case for most cellular organelles (mitochondria, Golgi, etc.). Electron tomography allows 3D reconstruction of a single object after acquisition of tilt series, corresponding to a set of 2D projection...

متن کامل

Electron Diffraction Based Tilt Angle Measurements in Electron Tomography

Electron tomography can provide three dimensional (3D) visualization of nanoscale objects in a transmission electron microscope (TEM) from a tilt series of projected images. The accuracy of the 3D reconstruction depends on quality of input parameters, including accurate alignment in real space and accuracy of tilt and azimuth angle measurements. Here we present an electron diffraction-based in-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultramicroscopy

دوره 60 3  شماره 

صفحات  -

تاریخ انتشار 1995