10-year results of a new low-monomer cement
نویسندگان
چکیده
BACKGROUND AND PURPOSE The properties and performance of a new low-monomer cement were examined in this prospective randomized, controlled RSA study. 5-year data have already been published, showing no statistically significant differences compared to controls. In the present paper we present the 10-year results. METHODS 44 patients were originally randomized to receive total hip replacement with a Lubinus SPII titanium-aluminum-vanadium stem cemented either with the new Cemex Rx bone cement or with control bone cement, Palacos R. Patients were examined using RSA, Harris hip score, and conventional radiographs. RESULTS At 10 years, 33 hips could be evaluated clinically and 30 hips could be evaluated with RSA (16 Cemex and 14 Palacos). 9 patients had died and 4 patients were too old or infirm to be investigated. Except for 1 hip that was revised for infection after less than 5 years, no further hips were revised before the 10-year follow-up. There were no statistically significant clinical differences between the groups. The Cemex cement had magnitudes of migration similar to or sometimes lower than those of Palacos cement. In both groups, most hips showed extensive radiolucent lines, probably due to the use of titanium alloy stems. INTERPRETATION At 10 years, the Cemex bone cement tested performed just as well as the control (Palacos bone cement).
منابع مشابه
Cement leakage and filling pattern study of low viscous vertebroplastic versus high viscous confidence cement
BACKGROUND Vertebral augmentation has recently evolved as a medical procedure for the treatment of vertebral compression fractures, the most common type of skeletal fractures related to osteoporosis. METHODS This study compared the cement leakage and filling behavior of 2 existing delivery systems (Confidence and Vertebroplastic; DePuy Spine, Raynham, MA). The Confidence system with the high ...
متن کاملDevelopment of new bone cement utilizing low toxicity monomers.
Acrylic bone cement is self-curing cement comprising of liquid and powder component of methyl methacrylate (MMA). It has been used extensively in orthopedics; however, adverse effects were associated with its use. Hence we investigated in this paper the possibility of new cement utilizing methacrylates with lower toxicity than MMA. LD50s of candidate monomers were determined with administration...
متن کاملThe Use of Nanoaccelerator in Cement Slurries in Low Temperature Well Conditions
It has long been known that temperature during circulation and after cement placement is one of the most important parameters for slurry design and the success in cement production. Conventional cements and low density cement slurries usually take a long time to set and cannot provide significant compressive strength. Therefore, it is important to design appropriate low density cement slurries ...
متن کاملMechanical Properties of Acrylic Bone Cement Containing the New Soluble Contrast Medium - Iohexol Hexaacetate
INTRODUCTION Acrylic bone cements, used in arthroplasty, incorporates contrast media to make them radiopaque and visible on X-ray images. However, today’s particulate contrast media cause three disadvantages to the acrylic bone cement, namely; third body wear, decreased mechanical properties and reduced biocompatibility. Iohexol hexaacetate (IHA) is a new iodide based non-ionic contrast medium,...
متن کاملAntibiotic Distribution in a Bone Cement Spacer Sample
Shiramizu K; Lovric V; Leung AMD; +Walsh WR Surgical & Orthopaedic Research Laboratories, University of New South Wales, Sydney, Australia [email protected] INTRODUCTION Deep infection after total joint replacement is a severe complication, and the use of antibiotic-loaded bone cement as a joint spacer is an established and efficient treatment method to treat infected arthroplasties. When pre...
متن کامل