Time-Resolved Immunofluorometry
نویسندگان
چکیده
We describe new methods for the detection of immunoglobulin G (IgG) and IgM rubella-specific antibodies in serum. The IgG assay was based on a solid-phase rubella antigen immobilization approach, and the IgM assay was based on the IgM capture assay principle. Both assays used biotinylated antibodies (anti-human IgG and antirubella monoclonal antibody, respectively). The tracer system was based on streptavidin labeled with
منابع مشابه
Assay of creatine kinase isoenzyme MB in serum with time-resolved immunofluorometry.
We describe the first time-resolved immunofluorometric assay for creatine kinase (EC 2.7.3.2) isoenzyme MB (CK-MB) in serum. The assay is based on the formation of the complex: solid-phase anti-CK-MB-CK-MB-biotinylated anti-CK-BB-streptavidin-BCPDA-Eu3+, where anti-CK-MB and anti-CK-BB are monoclonal antibodies against the CK isoenzymes MB and BB, respectively, and BCPDA is the europium chelato...
متن کاملImmunofluorometry of choriogonadotropin by time-resolved fluorescence spectroscopy, with a new europium chelate as label.
We describe a new "sandwich"-type non-isotopic immunoassay for human choriogonadotropin (hCG) in serum. In the assay, hCG is captured by a beta-subunit-specific monoclonal antibody, which is immobilized in a white microtiter well. The sandwich is completed by adding a second biotinylated monoclonal antibody specific for the whole hCG molecule. The degree of binding of biotinylated antibody, whi...
متن کاملDetection of BCR-ABL transcripts from the Philadelphia translocation by hybridization in microtiter wells and time-resolved immunofluorometry.
Two hybridization assays have been developed to detect BCR-ABL mRNA transcripts arising from the Philadelphia translocation. Both assays use time-resolved immunofluorometric detection of polymerase chain reaction-amplified BCR-ABL mRNA sequences hybridized to specific probes. In configuration I, biotinylated amplified target is immobilized onto streptavidin-coated wells and hybridized to a prob...
متن کاملSensitive, rapid procedure for time-resolved immunofluorometry of lutropin.
In this new immunofluorometric method for quantification of lutropin in serum, the "sandwich" principle is combined with time-resolved fluorescence measurements, with the europium chelate 4,7-bis(chlorosulfophenyl)-1,10-phenanthroline-2,9-dicarboxylic acid (BCPDA) used as label. A monoclonal antibody to the alpha-subunit of lutropin is adsorbed onto the walls of white-opaque microtiter wells to...
متن کاملDouble-label time-resolved immunofluorometry of lutropin and follitropin in serum.
We describe a procedure for the simultaneous immunofluorometric assay of lutropin and follitropin in human serum, based on the use of monoclonal antibodies and of the fluorescent lanthanides Eu3+ and Tb3+. The alpha-chain-specific antibody was used as a common capture antibody on the surfaces of microtitration strips. The anti-beta-follitropin antibody was labeled with Tb3+, the anti-beta-lutro...
متن کامل