Porosity Measurement Method by X-ray Computed Tomography

نویسنده

  • J. Prokop
چکیده

Therefore, the new method, called the grey level method, which reflects the phenomenon of image processing and computation of ration between the volume of voids and the total volume of the entire sample, was considered and improved in term of image noise and artifacts. The volumes of 2D CT image as a surface are achieved by means of integrating the surface with operations relating to image histogram. The porosity value is given form the curve of a porosity distribution. Subsequently, the properties of individual pores were measured and comparison with conventional destructive method of porosity computation was carried out. Data analysis and image processing were realized in Matlab.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Empirical correlation for porosity deduction from X-ray computed tomography (CT)

For obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as X-ray computed tomography, CT, seems to be precise and accurate. Porosity is deducted from the CT image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. More than one hundred samples with carbonate li...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Comparison of different segmentation methods for porosity evaluation in CFRP-reference samples with real porosity samples

The main objective of this work is quantitative evaluation of porosity in carbon fiber reinforced polymers (CFRP) with the help of X-ray computed tomography (XCT). For this purpose two types of sample were compared. Industrial porosity sample was obtained from an aeronautical industry. Artificially induced porosity samples were created by drilling holes with diameter 0.2 mm and 0.3 mm in non-po...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

An iterative method to estimate x-ray attenuation coefficients in computed tomography

Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008