Analytical validation and establishment of reference intervals for a ‘high-sensitivity’ cardiac troponin-T assay in horses

نویسندگان

  • E Shields
  • I Seiden-Long
  • S Massie
  • S Passante
  • R Leguillette
چکیده

BACKGROUND Cardiac troponin-I assays have been validated in horses.'High-sensitivity' cardiac troponin assays are now the standard in human cardiology. OBJECTIVE Appropriately validate the'high-sensitivity' cardiac Troponin-T (hscTnT) assay for clinical use in horses, establish reference intervals, determine the biological variation, and demonstrate assay utility in selected clinical cases. METHODS Analytical validation of the Roche hscTnT assay included within- and between-run precision, linear dose response, limit of quantitation (LoQ), stability, and comparison with cTn-I (iSTAT). Reference intervals and biological variation were determined using adult, healthy, Non-Competition Horses (N = 125) and Racing-Thoroughbreds (N = 178). HscTnT levels were measured in two horses with cardiac pathology. RESULTS The hscTnT demonstrates acceptable within-run (L1 = 6.5 ng/L, CV 14.9 %, L2 = 10.1 ng/L, CV 8.7 %, L3 = 15.3 ng/L, CV 5.4 %) and between-run precision (L1 = 12.2 ng/L, CV 8.4 %, L2 = 57.0 ng/L, CV 8.4 %, L3 = 256.0 ng/L, CV 9.0 %). The assay was linear from 3 to 391 ng/L. The LoQ was validated at 3 ng/L. Samples demonstrated insignificant decay over freeze-thaw cycle. Comparison with cTnI assay showed excellent correlation (range: 8.0-3535.0 ng/L, R(2) = 0.9996). Reference intervals: The upper 95(th) and 99(th) percentile of the hscTnT population distribution were 6.8 and 16.2 ng/L in Non-Competition Horses, and 14.0 and 23.2 ng/L in Racing-Thoroughbreds. Between-breed, diurnal effect, and between-day variation was below LoQ. Two clinical cases with presumed cardiac pathology had hscTnT levels of 220.9 ng/L and 5723.0 ng/L. CONCLUSIONS This benchmark study is the first to comply with CLSI guidelines, thus further establishing the performance characteristics of the hscTnT assay, and reference intervals in healthy horses. Two clinical cases demonstrated further the clinical utility of the assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical validation of a high-sensitivity cardiac troponin T assay.

BACKGROUND We report the development of a novel high-sensitivity cardiac troponin T (hs-cTnT) assay, a modification of the Roche fourth-generation cTnT assay, and validation of the analytical performance of this assay. METHODS Validation included testing of analytical sensitivity, specificity, interferences, and precision. We established the 99th percentile cutoff from healthy reference popul...

متن کامل

Biological and analytical variability of a novel high-sensitivity cardiac troponin T assay.

BACKGROUND High-sensitivity cardiac troponin assays will augment the frequency of increased results, making important the determination of reference change values to distinguish acute from chronic increases. We assessed short- and long-term biological variability of cardiac troponin T (cTnT) in healthy subjects with a novel high-sensitivity (hs) assay. METHODS We collected blood from 20 healt...

متن کامل

Cardiac enzyme in emergency medicine

Objective: Acute chest pain is an important and frequently occurring symptom in patients. Chest pain is often a sign of ischemic heart disease. Chest pain due to suspected Acute Coronary Syndrome (ACS) is responsible for a large and ijncreasing number of hospital attendances and admissions. Current practice for suspected ACS involves troponin testing 10–12 hours after symptom o...

متن کامل

Cardiac Troponin I as Compared to Troponin T for the Detection of Myocardial Damage in Horses

BACKGROUND Different cardiac troponin I (cTnI) assays give different results. Only 1 manufacturer has marketed troponin T (cTnT) assays. Therefore, cTnT often is preferred for detection of myocardial infarction in human patients. Studies of cTnT in horses are limited. OBJECTIVES To compare a cTnI and a high-sensitive cTnT assay (hs-cTnT) in horses. ANIMALS Cardiac troponin I and cTnT were d...

متن کامل

Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.

BACKGROUND The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2016