A Spatial Calibrated AER Contrast Retina with Adjustable Contrast Threshold

نویسندگان

  • J. A. Leñero-Bardallo
  • T. Serrano-Gotarredona
  • B. Linares-Barranco
چکیده

Address Event Representation (AER) is an emergent technology for assembling modular multi-blocks bio-inspired sensory and processing systems. Visual sensors (retinae) are among the first AER modules to be reported since the introduction of the technology. Spatial contrast AER retinae are of special interest since they provide highly compressed data flow without reducing the relevant information required for performing recognition. Reported AER contrast retinae perform a contrast computation based on the ratio between a pixel’s local light intensity and a spatially weighted average of its neighbourhood. This results in compact circuits, but with the penalty of all pixels generating output signals even if they sensed no contrast. In this paper we present a spatial contrast retina with bipolar output: contrast is computed as the relative difference between a pixel’s local light and its weighted spatial average. As a result, contrast includes a sign and the output will be zero if there is no contrast. Furthermore, an adjustable thresholding mechanism has been included, such that pixels remain silent until they sense an absolute contrast above the adjustable threshold. The pixel contrast computation circuit is based on Boahen’s Biharmonic operator contrast circuit, which has been improved to include mismatch calibration and adaptive current based biasing. As a result, the contrast computation circuit shows much less mismatch, is almost insensitive to ambient light illumination, and biasing is much less critical than in the original voltage biasing scheme. A full AER retina version has been fabricated. In the present paper we provide simulation and preliminary experimental results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی نقش ابتلا به تالاسمی در اختلال آستانه کانتراست بینایی

Background and purpose: Threshold contrast sensitivity could be considered as an important indicator of visual function in thalassemic patients. In this study the threshold of contrast sensitivity was investigated in patients with major and minor thalassemia and normal individuals. Material & methods: This cross-sectional study was conducted in 30 patients of thalassemia major (Desferal depen...

متن کامل

Spatial frequency adaptation: Threshold elevation and perceived contrast

We have measured the spread of contrast adaptation across the dimension of spatial frequency. Threshold elevation was tightly tuned to the adapting spatial frequency but became much broader as test contrast was increased. This means that, for a given test frequency, there are some frequencies which do not raise threshold but do result in a loss of perceived contrast. The contrast dependence, re...

متن کامل

A new approach to contrast enhancement in MAGICA gel dosimeter image with MRI technique

parameters that have to be measured in gel dosimetry. However, the resolution in gel is strongly dependant on gel composition. Selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. Materials and Methods: MAGICA polymer gel dosimeters were manufactured and irradia...

متن کامل

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

متن کامل

Interactions among spatial frequency and orientation channels adapted concurrently.

Interactions between size and orientation-specific mechanisms in the human visual system were investigated using a sequential adaptation technique. Subjects adapted to a vertical, 4 c/deg high-contrast (0.7) sinewave grating that was interleaved at a rate of 0.5 Hz with another adapting grating differing either in (1) spatial frequency or (2) orientation. Before and after adaptation contrast th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003