The relationship between myocardial integrated backscatter, perfusion pressure and wall thickness during isovolumic contraction: an isolated pig heart study.
نویسندگان
چکیده
To investigate the independent effect of myocardial wall thickness and myocardial perfusion pressure on integrated backscatter, experiments were designed in which integrated backscatter of normally perfused myocardial tissue was measured while changes in wall thickness during the cardiac cycle were reduced to a minimum. In nine blood-perfused isolated pig hearts, perfusion pressure was uncoupled from left ventricular pressure generation (Langendorff method) and isovolumic contraction and relaxation were realized by inserting a noncompressible water-filled balloon into the left ventricle. In a first experiment, at constant perfusion pressure (85 mmHg), the integrated backscatter (3-7 MHz), the myocardial wall thickness and the left ventricular pressure were determined simultaneously at various balloon volumes (5-25 mL). A quasistatic increase of balloon volume by 50% resulted in an average decrease of wall thickness of 6.5% (p < 0.01) and a mean increase in the integrated backscatter level of 1.1 dB (p < 0.01). Integrated backscatter levels increased statistically significant by 0.14 +/- 0.014 dB per percent decrease of wall thickness. Measurements of percentage end-systolic myocardial wall thickening ranged from -10% to +10%, mean 0.15 +/- 4.5% (NS from zero); whereas cyclic variation of integrated backscatter ranged from -3.9 to +3.9 dB, mean 0.19 +/- 1.5 dB (NS from zero). In a second experiment, at a constant midrange balloon volume, the same parameters were determined simultaneously at various perfusion pressures (20-120 mmHg). An increase in perfusion pressure by 50% resulted in a small but statistically significant increase of 1.5% in myocardial wall thickness, which could be explained by an increase of intravascular volume. The integrated backscatter levels did not change statistically significantly. Measurements of percentage end-systolic myocardial wall thickening ranged from -8.9 to +7.8%, mean 0.13 +/- 4.0% (NS from zero); whereas cyclic variation of integrated backscatter ranged from -1.8 to +4.2 dB, mean 0.37 +/- 1.3 dB (NS from zero). The magnitude of cyclic variation of integrated backscatter of myocardial tissue in a contractile state is reduced if myocardial muscle is prevented from normal thickening. In addition, changes in intravascular volume during the cardiac cycle have a negligible influence on the absolute backscatter level or its cyclic variation. We conclude, if only wall thickness and perfusion pressure are involved, that integrated backscatter is mainly determined by myocardial wall thickness.
منابع مشابه
Influence of data processing on cyclic variation of integrated backscatter and wall thickness in stunned porcine myocardium.
This study was performed to investigate the relationship between the cyclic variation of integrated backscatter and myocardial wall thickening in stunned myocardium. Different definitions of cyclic variation were evaluated to be able to compare with other studies. Ultrasound data were acquired from 10 open-chested Yorkshire pigs (25-33 kg) at baseline, during regional ischemia and during 30 min...
متن کاملComparative effects of hypoxia and ischemia in the isolated, blood-perfused dog heart: evaluation of left ventricular diastolic chamber distensibility and wall thickness.
To compare the effects of hypoxia and ischemia on left ventricular (LV) diastolic function, we studied 17 isolated, isovolumic dog hearts by measuring LV diastolic chamber distensibility (LV end diastolic pressure at constant volume), wall thickness, and myocardial pH in response to hypoxia at constant coronary flow or pressure versus global ischemia (zero coronary blood flow). Hypoxic perfusat...
متن کاملDoes Heart Affect Peripheral Vascular Resistance Following Myocardial Ischemia and Reperfusion?
Objective(s) The aim of this study was to investigate the overall effect of cardiac vasoactive factors during coronary occlusion and reperfusion on peripheral vascular tone, using a sequential isolated rabbit heart-ear perfusion model. Materials and Methods Isolated ears were perfused with the effluent of isolated hearts subjected to ischemia (30 min) and reperfusion (180 min, n=6). The comp...
متن کاملThe effect of an isovolumic left ventricle on the coronary vascular competence during reflow after global ischemia in the rat heart.
During global ischemia in isolated rat hearts, the development of contracture, due to irreversible myofilament sliding, causes reduction of left ventricle luminal volume. Also, a considerable area of the myocardium cannot be reperfused after 1 hour's global ischemia. The purpose of this study was to reduce myofilament sliding by placing a fluid-filled isovolumic balloon in the left ventricular ...
متن کاملContractile State of the Heart Characterized by Force-Velocity Relations in Variably Afterloaded and Isovolumic Beats
• The performance of the heart has been described traditionally in terms of relations between the end diastolic volume or filling pressure of the ventricles and their stroke volume or stroke work,the latter relationship having been extended to include a family of "ventricular function curves."" While these measurements provide considerable insight into the level of cardiac performance, recent s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in medicine & biology
دوره 22 1 شماره
صفحات -
تاریخ انتشار 1996