Structural Layers of Ex Vivo Rat Hippocampus at 7T MRI

نویسندگان

  • Jeanine Manuella Kamsu
  • Jean-Marc Constans
  • Franck Lamberton
  • Patrick Courtheoux
  • Pierre Denise
  • Bruno Philoxene
  • Maelle Coquemont
  • Stephane Besnard
چکیده

Magnetic resonance imaging (MRI) applied to the hippocampus is challenging in studies of the neurophysiology of memory and the physiopathology of numerous diseases such as epilepsy, Alzheimer's disease, ischemia, and depression. The hippocampus is a well-delineated cerebral structure with a multi-layered organization. Imaging of hippocampus layers is limited to a few studies and requires high magnetic field and gradient strength. We performed one conventional MRI sequence on a 7T MRI in order to visualize and to delineate the multi-layered hippocampal structure ex vivo in rat brains. We optimized a volumic three-dimensional T2 Rapid Acquisition Relaxation Enhancement (RARE) sequence and quantified the volume of the hippocampus and one of its thinnest layers, the stratum granulare of the dentate gyrus. Additionally, we tested passive staining by gadolinium with the aim of decreasing the acquisition time and increasing image contrast. Using appropriated settings, six discrete layers were differentiated within the hippocampus in rats. In the hippocampus proper or Ammon's Horn (AH): the stratum oriens, the stratum pyramidale of, the stratum radiatum, and the stratum lacunosum moleculare of the CA1 were differentiated. In the dentate gyrus: the stratum moleculare and the stratum granulare layer were seen distinctly. Passive staining of one brain with gadolinium decreased the acquisition time by four and improved the differentiation between the layers. A conventional sequence optimized on a 7T MRI with a standard receiver surface coil will allow us to study structural layers (signal and volume) of hippocampus in various rat models of neuropathology (anxiety, epilepsia, neurodegeneration).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volumetric structural magnetic resonance imaging (MRI) of the rat hippocampus following kainic acid (KA) treatment.

An in vivo MRI study employing a high field (7T) magnet and a T1- and T2-weighted imaging sequence with subsequent histopathological evaluations was undertaken to develop and evaluate MRI-based volumetric measurements in the rat. The brain structures considered were the hippocampus, the cingulate cortex, the retrosplenial granular cortex and the ventricles. Control (n=3) and kainic acid (KA; n=...

متن کامل

Mapping of the internal structure of human habenula with ex vivo MRI at 7T

The habenula is a small but important nucleus located next to the third ventricle in front of the pineal body. It helps to control the human reward system and is considered to play a key role in emotion, showing increased activation in major depressive disorders. Its dysfunction may underlie several neurological and psychiatric disorders. It is now possible to visualize the habenula and its ana...

متن کامل

Visualization of the amygdalo-hippocampal border and its structural variability by 7T and 3T magnetic resonance imaging.

The amygdala and the hippocampus are two adjacent structures in the medial temporal lobe that have been broadly investigated in functional and structural neuroimaging due to their central importance in sensory perception, emotion, and memory. Exact demarcation of the amygdalo-hippocampal border (AHB) is, however, difficult in conventional structural imaging. Recent evidence suggests that, due t...

متن کامل

In vivo detection of cerebral cortical microinfarcts with high-resolution 7T MRI.

Cerebrovascular disease has an important role in cognitive decline and dementia. In this context, cerebral microinfarcts are attracting increasing attention, but these lesions could thus far not be detected in vivo. The aim of this study was to try to identify possible cortical microinfarcts on high-resolution 7T in vivo magnetic resonance imaging (MRI) and to perform a histopathologic validati...

متن کامل

In vivo high-resolution MRI (7T) of femoro-tibial cartilage changes in the rat anterior cruciate ligament transection model of osteoarthritis: a cross-sectional study.

OBJECTIVE To assess OA-related changes in mean compartmental femorotibial cartilage thickness in rat knees by three-dimensional (3D) MRI (7T). METHODS MRI was performed in vivo at 7T on OA and untouched contralateral knee joints. Gradient Echo Fast Imaging 3D MR images were acquired sequentially in surgically induced OA (D0) in 40 Wistar rats (anterior cruciate ligament transection). Mean fem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013