Analysis and design for RCD clamped snubber used in output rectifier of phase-shift full-bridge ZVS converters
نویسندگان
چکیده
Detailed analysis and parameter design for a resistorcapacitor-diode (RCD) clamped snubber used in the output rectifier of phase-shift full-bridge zero-voltage-switching (PS-FB-ZVS) converters are presented. Design equations and some properties of the clamped circuit are highlighted.
منابع مشابه
Analysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype
One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...
متن کاملAnalysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype
One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...
متن کاملDesign of PI and Fuzzy Controller for High-Efficiency and Tightly Regulated Full Bridge DC-DC Converter
The controller is used to improve the dynamic performance of DC-DC converter by achieving a robust output voltage against load disturbances. This paper presents the performance of PI and Fuzzy controller for a phaseshifted zerovoltage switched full-bridge PWM (ZVS FBPWM) converters with a closed loop control. The proposed converter is regulated with minimum overshoot and good stability. In this...
متن کاملComparison between Phase-Shift Full-Bridge Converters with Noncoupled and Coupled Current-Doubler Rectifier
This paper presents comparison between phase-shift full-bridge converters with noncoupled and coupled current-doubler rectifier. In high current capability and high step-down voltage conversion, a phase-shift full-bridge converter with a conventional current-doubler rectifier has the common limitations of extremely low duty ratio and high component stresses. To overcome these limitations, a pha...
متن کاملDesign Considerations and Performance Evaluation of Single-Stage TAIPEI Rectifier for HVDC Distribution Applications
Design considerations and performance evaluations of a three-phase, four-switch, single-stage, isolated zero-voltage-switching (ZVS) rectifier are presented. The circuit is obtained by integrating the three-phase, two-switch, ZVS, discontinuous-current-mode (DCM), boost power-factorcorrection (PFC) rectifier, named for short the TAIPEI rectifier, with the ZVS full-bridge (FB) phase-shift dc/dc ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE Trans. Industrial Electronics
دوره 45 شماره
صفحات -
تاریخ انتشار 1998