Examination of the intrarenal hematocrit ratio with the techinque of circulatory stop-flow in dogs.
نویسندگان
چکیده
Estimates of the intrarenal hematocrit ratio vary widely, depending on the techniques used for its determination. Computation of blood volume from the product of mean transit time of labeled erythrocytes and albumin, and minute volume blood flow, yields values averaging approximately 90% of the systemic vessel hematocrit. To the other extreme are values that are slightly less than half of the systemic hematocrit ratio based on the determination of total renal blood volume by labeled red cells and albumin. Intermediate values are obtained by methods involving draining the blood from the kidney and measuring its hematocrit ratio. The current investigation, by a technique of circulatory stop-flow, has shown that a substantial fluid shift occurs in the kidney within 2 minutes of circulatory arrest, so that interstitial fluid, supplemented by fluid reabsorbed by the nephrons, dilutes the erythrocytes within the peritubular capillaries to reduce the hematocrit ratio to almost half of the systemic figure. The drainage methods are subject to error as a result of this mechanism, but if such fluid shifts are taken into account, values for the intrarenal hematocrit closer to the ratio of systemic blood can be anticipated. ADDITIONAL
منابع مشابه
Distribution of renal blood flow in dogs with congestive heart failure.
Studies were performed to determine whether the intrarenal distribution of cortical blood flow is altered in congestive heart failure. Utilizing the radioactive microsphere method, we studied eight dogs that developed congestive heart failure secondary to the construction of an aortocaval fistula. They had marked reduction in total renal blood flow not accompanied by intracortical redistributio...
متن کاملMathematical Simulation for the Effects of Flow Control Devices in a Six- strand Tundish in Continuous Casting of Steel Billet
The method of continuous casting of steel is now often used in the metallurgical industry, due to the increasing demand for the production of high – quality steel. An important device of continuous casting machine is the tundish, in which a stabilized steel flow has a crucial effect on the quality and efficiency conditions of the continuous casting process. In this study fluid flows in a six – ...
متن کاملRelationship between renin and intrarenal hemodynamics in hemorrhagic hypotension.
In order to investigate the possible role of the renin-angiotensin system in the regulation of intrarenal hemodynamics in hemorrhagic hypotension (HH), seven mongrel dogs have been studied under the following conditions: (a) Control, (b) HH (mean arterial pressure 70 mm Hg), and (c) HH + alpha adrenergic blockade by phenoxybenzamine (HH + POB). The following parameters were obtained for the rig...
متن کاملReduced intrarenal resistance and autoregulatory capacity after hyperoncotic dextran.
NAVAR, L. G., P. G. BAER, S. L. WALLACE, AND J. K. McI DANIEL. Reduced intrarenal resistance and autoregulatory capacity after hvperoncotic dextran. Am. J. Physiol. 221(l): 329-334. 1971.Renal hemodvnamic and urine flow responses to infusions of hyperoncotic dextran solutions have been studied in anesthetized dogs. Following infusion of 300-500 ml of a 12yh dextran solution, the renal blood flo...
متن کاملEvaluation of Carpal Tunnel Syndrome by Laser Doppler Flowmetry
Background:Autonomic disturbance can leads to blood flow changes that can be studied by various methods. Objective: To assess the blood flow changes in patients with severe carpal tunnel syndrome by laser Doppler flowmetry Methods:Ten patients with severe unilateral carpal tunnel syndrome confirmed by electrodiagnostic examination enrolled in this study. Patients comprised one man and nine wom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 25 6 شماره
صفحات -
تاریخ انتشار 1969