Sagittal focusing of synchrotron radiation diffracted on the walls of a longitudinal hole drilled into a single-crystal monochromator.
نویسندگان
چکیده
A very simple method of sagittal focusing of X-ray synchrotron radiation is presented. A special ray-tracing program which utilizes the diffraction-refraction effect is developed. It is demonstrated both by ray-tracing simulations and by an experiment whereby a reasonably good sagittal concentration of 8 keV synchrotron radiation may be achieved by diffraction on the walls of a cylindrical hole drilled into an Si crystal. The holes were drilled parallel to the (111) planes and their diameter, 1 mm, was chosen so that the focusing distance fits the geometrical arrangement of beamline BM5 at the ESRF. Two such crystals have been used in a dispersive and non-dispersive arrangement. The better result was achieved using the dispersive arrangement. The intensity at the centre of the focus is increased by five times with respect to unfocused radiation. Excellent agreement exists between the ray-tracing simulations and experimental results.
منابع مشابه
Heat bump on a monochromator crystal measured with X-ray grating interferometry.
Deformation of the first crystal of an X-ray monochromator under the heat load of a high-power beam, commonly referred to as `heat bump', is a challenge frequently faced at synchrotron beamlines. Here, quantitative measurements of the deformations of an externally water-cooled silicon (111) double-crystal monochromator tuned to a photon energy of 17.6 keV are reported. These measurements were m...
متن کاملA high-throughput structural biology/proteomics beamline at the SRS on a new multipole wiggler.
The North West Structural Genomics Centre's beamline, MAD10, at the SRS receives the central part of the radiation fan (0.5 mrad vertically, 4 mrad horizontally) produced by a new 2.46 T ten-pole wiggler. The optical arrangement of the beamline consists of a Rh-coated collimating Si mirror, a fixed-exit-beam double-crystal monochromator with sagittal bending for horizontal focusing and a second...
متن کاملSynchrotron radiation study of the relation between structure and strain in polyurethane elastomers.
This paper describes a system for the study of the relation between structure and applied strain in thermoplastic polyurethane elastomers using the Australian National Beamline Facility at the Photon Factory, KEK, Tsukuba, Japan. The system uses the sagittal focusing monochromator at beamline 20B to provide a high-intensity focused beam which then falls on the specimen mounted in a miniature te...
متن کاملFixed-height exit bender of synchrotron X-rays above 40 keV.
A crystal bender for sagittal focusing has been designed for standard monochromators at SPring-8. The bender does not move the position of the crystal center when the bending radius is changed. Sagittal focusing from 40 keV to 60 keV was achieved by using Si(311) double crystals. The flux density of the focused beam measured at 40 keV was 15 times higher than that of the unfocused beam. The hei...
متن کاملBeamline X29: a novel undulator source for X-ray crystallography.
A high-flux insertion device and beamline for macromolecular crystallography has been built at the National Synchrotron Light Source (NSLS) that employs a mini-gap undulator source developed by the NSLS. The mini-gap undulator at beamline X29 is a hybrid-magnet device of period 12.5 mm operating at proven gaps of 3.3-10 mm. The beamline provides hard X-rays for macromolecular crystallography ex...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of synchrotron radiation
دوره 8 Pt 6 شماره
صفحات -
تاریخ انتشار 2001