Markers of good performance in mammography depend on number of annual readings.
نویسندگان
چکیده
PURPOSE To explore relationships between reader performance and reader characteristics in mammography for specific radiologist groupings on the basis of annual number of readings. MATERIALS AND METHODS The institutional review board approved the study and waived the need for patient consent to use all images. Readers gave informed consent. One hundred sixteen radiologists independently reviewed 60 mammographic cases: 20 cases with cancer and 40 cases with normal findings. Readers located any visualized cancer, and levels of confidence were scored from 1 to 5. A jackknifing free response operating characteristic (JAFROC) method was used, and figures of merit along with sensitivity and specificity were correlated with reader characteristics by using Spearman techniques and standard multiple regressions. RESULTS Reader performance was positively correlated with number of years since qualification as a radiologist (P ≤ .01), number of years reading mammograms (P ≤ .03), and number of readings per year (P ≤ .0001). The number of years since qualification as a radiologist (P ≤ .004) and number of years of reading mammograms (P ≤ .002) were negatively related to JAFROC values for radiologists with annual volumes of less than 1000 mammographic readings. For individuals with more than 5000 mammographic readings per year, JAFROC values were positively related to the number of years that the reader was qualified as a radiologist (P ≤ .01), number of years of reading mammograms (P ≤ .002), and number of hours per week of reading mammograms (P ≤ .003). Number of mammographic readings per year was positively related with JAFROC scores for readers with an annual volume between 1000 and 5000 readings (P ≤ .03). Differences in JAFROC scores appear to be more related to specificity than location sensitivity, with the former demonstrating significant relationships with four of the five characteristics analyzed, whereas no relationships were shown for the latter. CONCLUSION Radiologists' determinants of performance are associated with annual reading volumes. Ability to recognize normal images is a discriminating factor in individuals with a high volume of mammographic readings.
منابع مشابه
Evaluation of Ultrasonography and Mammography in Diagnosis of Mammary Gland Tumor in Bitches: Based on Tumor Markers
Objective- This study refers to the role of ultrasonography in the diagnosis of mammary gland tumor in bitches as a complementary diagnostic method and its ultimate goal is to evaluate the results of mammography with the positive results of ultrasonography. Design- Prospective study. Animals- 12 German Shepherd bitches with swollen mass in the mammary gland region (group I) and 12 h...
متن کاملارزیابی دز و کیفیت تصویر در آزمون های ماموگرافی در مراکز ماموگرافی شهر تهران
Abstract Background: Breast cancer is one of the most common form of cancer among women. Diagnosis in the early stage of emergence is the most effective way to reduce the mortality caused by this disease. Mammography, the safest and most accurate imaging test for the identification of breast cancer, required high quality images along applying the lowest possible dose to sensitive tissues of the...
متن کاملEducational software as a tool for teaching & learning of digital mammography*
OBJECTIVE: The present study was aimed at evaluating the performance of residents trained in the reading of conventional and digital mammography images with a specific computational tool. MATERIALS AND METHODS: The training was accomplished in the Laboratory of Medical Images Qualification (QualIM – Laboratório de Qualificação de Imagens Médicas). Residents in radiology performed approximately ...
متن کاملCollaborative Modeling of the Benefits and Harms Associated With Different U.S. Breast Cancer Screening Strategies.
BACKGROUND Controversy persists about optimal mammography screening strategies. OBJECTIVE To evaluate screening outcomes, taking into account advances in mammography and treatment of breast cancer. DESIGN Collaboration of 6 simulation models using national data on incidence, digital mammography performance, treatment effects, and other-cause mortality. SETTING United States. PATIENTS Av...
متن کاملCalculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography
Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 269 1 شماره
صفحات -
تاریخ انتشار 2013