Removal of ECG Artifacts from Myoelectric Prosthesis Control Signals

نویسندگان

  • Ping Zhou
  • Madeleine M. Lowery
  • Richard F. ff Weir
  • Todd A. Kuiken
چکیده

Abstract We investigated removal of electrocardiogram (ECG) artifacts from the myoelectric prosthesis control signals, taken from the reinnervated pectoralis muscles of a patient with bilateral amputations at shoulder disarticulation level. The performance of various ECG artifact removal methods including high pass filtering, spike clipping, template subtracting, wavelet thresholding and adaptive filtering was presented. In particular, considering the clinical requirements and memory limitation of commercial prosthesis controllers, we further explored suitable means of ECG artifact removal for clinical application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complexity Analysis of Surface EMG for Overcoming ECG Interference toward Proportional Myoelectric Control

Electromyographic (EMG) signals from muscles in the body torso are often contaminated by electrocardiography (ECG) interferences, which consequently compromise EMG intensity estimation. The ECG interference has become a barrier to proportional control of myoelectric prosthesis using a neural machine interface called targeted muscle reinnervation (TMR), which involves transferring the residual a...

متن کامل

Removal of Artifacts from ECG Signal Using RLS Based Adaptive Filter: A Review

The electrocardiogram (ECG) is used for diagnosis of heart diseases. In a few circumstances the recorded ECG signals are corrupted by various noise signals caused by power line interference, base line wander, electrode movement, muscular movement (EMG) etc. These noise signals are known as artifacts. These artifacts mislead the diagnosis of heart which is not desired. To avoid this problem caus...

متن کامل

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

متن کامل

Myoelectric Control of Prosthetic Devices for Rehabilitation

Bio-signals patterns analysis problems have enjoyed a rapid increase in popularity in the past few years. The electromyography (EMG) signal, also referred to as the Myoelectric signal (MES), recorded at the surface of the skin, is one of the biosignals generated by the human body, representing a collection of electrical signals from the muscle fibre, acting as a physical variable of interest si...

متن کامل

Denoising of ECG Signals with Adaptive Filtering Algorithms & Patch Based Method

ECG signals have been proven a very versatile tool for detection of cardiovascular diseases. But during recording of these signals, the ECG data gets contaminated by various noise signals caused by power line interference, base line wander, electrode movement, muscle movement (EMG) etc. These noise signals are known as artifacts. These artifacts mislead the diagnosis of heart which is not desir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005