Wear Resistance of Bulk-fill Composite Resin Restorative Materials Polymerized under different Curing Intensities.

نویسنده

  • Fahad Alkhudhairy
چکیده

INTRODUCTION The aim of this study was to assess the wear resistance of four bulk-fill composite resin restorative materials cured using high- and low-intensity lights. MATERIALS AND METHODS Twenty-four samples were prepared from each composite resin material (Tetric N-Ceram, SonicFill, Smart Dentin Replacement, Filtek Bulk-Fill) resulting in a total of 96 samples; they were placed into a mold in a single increment. All of the 96 samples were cured using the Bluephase N light curing unit for 20 seconds. Half of the total specimens (n = 48) were light cured using high-intensity output (1,200 mW/cm2), while the remaining half (n = 48) were light cured using low-intensity output (650 mW/cm2). Wear was analyzed by a three-dimensional (3D) noncontact optical profilometer (Contour GT-I, Bruker, Germany). Mean and standard deviation (SD) of surface loss (depth) after 120,000 cycles for each test material was calculated and analyzed using one-way analysis of variance (ANOVA) with a significance level at p < 0.05. RESULTS The least mean surface loss was observed for SonicFill (186.52 urn) cured using low-intensity light. No significant difference in the mean surface loss was observed when comparing the four tested materials with each other without taking the curing light intensity into consideration (p = 0.352). A significant difference in the mean surface loss was observed between SonicFill cured using high-intensity light compared with that cured using low-intensity light (p < 0.001). CONCLUSION A higher curing light intensity (1,200 mW/cm2) had no positive influence on the wear resistance of the four bulk-fill composite resin restorative materials tested compared with lower curing light intensity (650 mW/cm2). Furthermore, SonicFill cured using low-intensity light was the most wear-resistant material tested, whereas Tetric N-Ceram cured using high-intensity light was the least wear resistant. CLINICAL SIGNIFICANCE The wear resistance was better with the newly introduced bulk-fill composite resins under low-intensity light curing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative Microhardness and Flexural Strength of Different Bulk Fill Resin Composite Restorative Materials

Aim: to find out if there is a significant difference in the curing efficiency at the claimed 4 mm depth and in the mechanical properties between the tested pasteform bulk fill resin composite materials. Materials and Methods: Three paste-consistency bulk-fill resin composites were used in this study (Filtek bulk fill3M; X-trafilVoco; and SonicFill bulk-fillKerr). For the microhardness testing,...

متن کامل

The effect of curing intensity on mechanical properties of different bulk-fill composite resins

OBJECTIVE The purpose of this study was to investigate the effects of two curing light intensities on the mechanical properties (Vickers microhardness, compressive strength, and diametral tensile strength) of bulk-fill resin-based composites (RBCs). MATERIALS AND METHODS Four commercially available bulk-fill RBCs (Tetric® N-Ceram, SonicFill™, Smart Dentin Replacement (SDR™) Posterior Flowable...

متن کامل

In Vitro Solubility and Wear Rates of Silorane and Dimethacrylate Resin Based Composite Restorative Materials under Different pH Conditions

BACKGROUND The purpose of this study was to evaluate the effect of different pH solutions on the solubility and wear resistance of Silorane and dimethacrylate resin based composite restorative materials. MATERIALS AND METHODS Two different resin based restorative materials (Filtek Silorane P90 and hybrid composite Z100) were tested. Different pH solutions (2.5 and 5) also were used. A total o...

متن کامل

Effect of Curing Time on Polymerization Rate of Bulk-Fill Composite Resins

Objectives: The aim of this study was to compare polymerization depth of two bulk-fill and one conventional composite cured for different times. Methods: This in vitro experimental study was conducted on 54 composite samples (2&times;4&times;10mm) fabricated of Tetric N-Ceram bulk-fill, x-tra fil bulk-fill, and Grandio conventional composite cured for 20, 30, and 40 seconds. The microhardnes...

متن کامل

Properties of dual-cure, bulk-fill composite resin restorative materials.

The purpose of this study was to compare the properties of 2 new dual-cure, bulk-fill restorative composite resins to those of a hybrid composite resin material. Depth of cure, fracture toughness, porosity, microleakage, and volumetric shrinkage properties were examined. With the exception of fracture toughness, significant differences were found among materials. Compared to the incrementally p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2017