Electrochemical modification of a graphite platform for a solid sampling electrothermal atomic absorption spectrometry of mercury.
نویسندگان
چکیده
An electrodeposited palladium and iridium/gold mixture has been investigated as a chemical modifier for mercury determination in environmental samples by solid sampling electrothermal atomic absorption spectrometry. Electrochemical procedures of platform surface modification performed in a cell with 20 ml of solution, and in a drop of modifier solution have been optimized. Simple electrolysis in a drop was found to be the most consistent, taking the reproducibility as the major criterion. A total mass of 250 µg of electrodeposited palladium or an iridium/gold mixture was used. The lifetime of 60 - 70 firings for a deposited iridium/gold mixture was smaller than that for palladium with a lifetime of 100 - 120 firings. The detection limit was 120 pg Hg. Different sample masses of between 0.1 and 10 mg were weighed into modified platforms according to the mercury content. The results obtained for mercury in environmental samples as soils, sediments and plant, using solid sampling and calibration against aqueous standards stabilized by potassium permanganate, were in good agreement with those achieved by using the thermal deposition of modifiers and with measurements by pyrolysis atomic absorption spectrometry with gold amalgamation.
منابع مشابه
Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry
Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation of mercury in calibration solutions and its thermal stabilization in a solid sampling platform. ...
متن کاملMonitoring and Method development of Hg in Istanbul Airborne Particulates by Solid Sampling Continuum Source-High Resolution Electrothermal Atomic Absorption Spectromerty
In this work, a method has been developed and monitoring for the determination of mercury in PM2.5 airborne particulates by solid sampling high-resolution continuum source electrothermal atomic absorption spectrometry. The PM2.5 airborne particulates were collected on quartz filters using high volume samplers (500 L/min) in Istanbul (Turkey) for 96 hours every month in one year. At first, exper...
متن کاملEvaluation of solid sampling-electrothermal vaporization- inductively coupled plasma mass spectrometry and solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of Cr in various materials using solution- based calibration approaches
M. Resano, E. Garcia-Ruiz, F. Vanhaecke, C. Crespo and M. A. Belarra Laboratory of Analytical Chemistry, Ghent University, Institute for Nuclear Sciences, Proeftuinstraat 86, B-9000 Ghent, Belgium Technological Institute of Aragón, Laboratory of Mechanics and New Materials, Marı́a de una 8, E-50018 Zaragoza, Spain Department of Analytical Chemistry, Faculty of Sciences, University of Zaragoza, P...
متن کاملUtilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples
In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...
متن کاملElimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 26 9 شماره
صفحات -
تاریخ انتشار 2010