Improvement of cervicocranial i.v. digital subtraction angiography with pixel remasking and cardiac gating.
نویسندگان
چکیده
A Philips DVI 2 apparatus* was used, and the technique has been described [8] . A total of 264 carotid bifurcations were studied retrospectively , 130 with and 134 without cardiac gating and postprocessing with pixel shift (Fig . 1 ). Only patients without renal failure or major cardiac disease were included. The ideal study of an area of interest consisted of two or more views with no movement of the patient or superimposition of vessels (Fig . 2). "See through " superimposition was accepted. The relevant carotid siphon was assessed in 31 patients whom the reviewer thought had a lesion of the common carotid bifurcation that was suitable for endarterectomy.
منابع مشابه
Postprocessing techniques for time-resolved contrast-enhanced MR angiography.
The purpose of this study was to improve dynamic two-dimensional projection magnetic resonance digital subtraction angiography by using remasking and filtering postprocessing techniques. Four methods were evaluated in 50 patients: default mask subtraction, remasked subtraction, filtering based on the SD, and linear filtering. The results demonstrated that postprocessing techniques such as linea...
متن کاملI.v. and intraarterial hybrid digital subtraction angiography: clinical evaluation.
Temporal/energy (hybrid) subtraction is a technique for removing soft-tissue motion artifact from digital subtraction angiograms. The diagnostic utility of hybrid subtraction for i.v. and intraarterial angiography was assessed in the first 9 months of operation of a dedicated production system. In i.v. carotid arteriography (N = 127), hybrid subtraction (H) provided a double-profile projection ...
متن کاملImage Warping for Accurate Digital Subtraction Angiography
This paper describes a system for sub-pixel registration of mask and opacified digital X-ray images so that the mask image can be accurately subtracted out from the opacified image. Our technique results in digital subtraction angiograms (DSAs) with fewer artifacts and better contrast.
متن کاملReduction of patient motion artifacts in digital subtraction angiography: evaluation of a fast and fully automatic technique.
The performance of an automatic technique for the reduction of patient motion artifacts in digital subtraction angiography was evaluated. Four observers assessed the quality of 104 cerebral digital subtraction angiographic images that were processed by means of both the automatic technique and manual pixel shifting. The automatic technique resulted in better image quality and was considerably l...
متن کاملContrast-enhanced MR angiography and digital subtraction angiography in living renal donors: diagnostic agreement, impact on decision making, and costs
Health technology The authors studied contrast-enhanced magnetic resonance angiography (MRA) and digital subtraction angiography (DSA). MR images were obtained using a 1.5-T MR scanner (Signa CV/I, GE Healthcare) with a torso phased-array coil. Digital subtraction images were obtained using a 38-cm field of view and an image matrix of 1,024 x 1,024 pixels (Integris V3000, Philips Medical System...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 10 5 Suppl شماره
صفحات -
تاریخ انتشار 1989