Assessment of a neck-based treatment and monitoring device for positional obstructive sleep apnea.

نویسندگان

  • Daniel J Levendowski
  • Sean Seagraves
  • Djordje Popovic
  • Philip R Westbrook
چکیده

STUDY OBJECTIVES A majority of patients diagnosed with obstructive sleep apnea are position dependent whereby they are at least twice as severe when sleeping supine (POSA). This study evaluated the accuracy and efficacy of a neck-worn device designed to limit supine sleep. The study included nightly measurements of snoring, sleep/wake, time supine, and the frequency and duration of feedback to monitor compliance. METHODS Thirty patients between ages 18 and 75 years, BMI ≤ 35 with an overall apnea-hypopnea index (AHI) ≥ 5 and an overall AHI ≥ 1.5 times the non-supine AHI, and an Epworth score ≥ 5 were prospectively studied. Subjective reports and polysomnography were used to assess efficacy resulting from 4 weeks of in-home supine-avoidance therapy and to measure device accuracy. From 363 polysomnography reports, 209 provided sufficient positional data to estimate one site's prevalence of positional OSA. RESULTS In 83% of participants exhibiting > 50% reduction in overall AHI, the mean and median reductions were 69% and 79%. Significant reductions in the overall and supine AHI, apnea index, percent time SpO2 < 90%, and snoring contributed to significant improvements in stage N1 and N2 sleep, reductions in cortical arousals and awakenings, and improved depression scores. Supine position was under-detected by > 5% in 3% of cases. Sleep efficiency by neck actigraphy was within 10% of polysomnography in 87% of the studies when position feedback was delivered. The prevalence of POSA was consistently > 70% when the overall AHI was < 60. CONCLUSIONS The neck position therapy device is accurate and effective in restricting supine sleep, improving AHI, sleep architecture and continuity, and monitoring treatment outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Biofeedback Therapy on Cardiovascular and Respiratory Indices in NREM Sleep Parasomnias with Obstructive Sleep Apnea: A Case study

Introduction: Non-REM parasomnias are a relatively common condition in the general human population. Current treatment plans are usually based on small case series and reports. Considering the effects of sleep disorders on different aspects of human life and the failure of pharmacological treatments in this field, the present study was designed to investigate a case of this sleep disorders with...

متن کامل

Probability of obstructive sleep apnea in male patients with systolic heart failure and some related factors

Background and Purpose: Sleep breathing disorders have a negative impact on the illness outcome and quality of life in patients with heart failure. This study was conducted to investigate the probability of obstructive sleep apnea in men with heart failure and some related factors. Method: This was a cross-sectional study conducted on 100 male patients with systolic heart failure selected throu...

متن کامل

The effect of positional dependency on outcomes of treatment with a mandibular advancement device.

OBJECTIVE To evaluate retrospectively the efficacy of the mandibular advancement device (MAD) in patients with obstructive sleep apnea in terms of positional dependency. DESIGN Retrospective analysis. SETTING Academic tertiary referral center. PATIENTS One hundred patients with obstructive sleep apnea treated with the MAD at the Department of Otorhinolaryngology sleep clinic were included...

متن کامل

Clinical validation of the Bedbugg in detection of obstructive sleep apnea.

OBJECTIVE To validate the accuracy of the Bedbugg, a new home monitoring device for diagnosis of obstructive sleep apnea. STUDY DESIGN AND SETTING Simultaneous sleep monitoring was performed by formal polysomnography and by Bedbugg. Monitoring was performed in a university sleep center in 42 subjects who had previously been scheduled for polysomnography. RESULTS The correlation for the apne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید