Multi-step microfluidic droplet processing: kinetic analysis of an in vitro translated enzyme.

نویسندگان

  • Linas Mazutis
  • Jean-Christophe Baret
  • Patrick Treacy
  • Yousr Skhiri
  • Ali Fallah Araghi
  • Michael Ryckelynck
  • Valérie Taly
  • Andrew D Griffiths
چکیده

Microdroplets in water-in-oil emulsions can be used as microreactors with volumes 10(3) to 10(9) times smaller than the smallest working volumes in a microtitre plate well (1-2 microL). However, many reactions and assays require multiple steps where new reagents are added at defined times, to start, modify or terminate a reaction. The most flexible way to add new reagents to pre-formed droplets is by controlled, pairwise droplet fusion. We describe a droplet-based microfluidic system capable of performing multiple operations, including pairwise droplet fusion, to analyze complex and sequential multi-step reactions. It is exemplified by performing a series of six on-chip and two off-chip operations which enable the coupled in vitro transcription and translation of cotA laccase genes in droplets and, after performing a controlled fusion with droplets containing laccase assay reagents, the end-point and kinetic analysis of the catalytic activity of the translated protein. In vitro translation and the laccase assay must be performed sequentially as the conditions for the laccase assay are not compatible with in vitro translation. Droplet fusion was performed by electrocoalescence at a rate of approximately 3000 fusion events per second and nearly 90% of droplets were fused one-to-one (one droplet containing in vitro translated laccase fused to one droplet containing the reagents for the laccase assay). The ability to uncouple the enzymatic assay from in vitro translation greatly extends the range of activities of in vitro translated proteins that can potentially be screened in droplet-based microfluidic systems. Furthermore, the system also opens up the possibility of performing a wide range of other new (bio)chemical reactions in droplets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study of Droplet Generation Process in a Microfluidic Flow Focusing

Microfluidic flow focusing devices have been utilized for droplet generation on account of its superior control over droplet size. Droplet based microfluidics addressed many scientific issues by providing a novel technological platform for applications such as biology, pharmaceutical industry, biomedical studies and drug delivery. This study numerically investigated the droplet generation proce...

متن کامل

Fluorescent Contrast agent Based on Graphene Quantum Dots Decorated Mesoporous Silica Nanoparticles for Detecting and Sorting Cancer Cells

Background and Objectives: The inability of classic fluorescence-activated cell sorting to single cancer cell sorting is one of the most significant drawbacks of this method. The sorting of cancer cells in microdroplets significantly influences our ability to analyze cancer cell proteins. Material and Methods: We adapted a developed microfluidic device as a 3D in vitro model to sorted MCF-7 c...

متن کامل

Droplet-based microfluidic lab-on-a-chip for glucose detection

A microfluidic lab-on-a-chip (LoC) platform for in vitro measurement of glucose for clinical diagnostic applications is presented in this paper. The LoC uses a discrete droplet format in contrast to conventional continuous flow microfluidic systems. The droplets act as solution-phase reaction chambers and are manipulated using the electrowetting effect. Glucose is measured using a colorimetric ...

متن کامل

Centrifugal step emulsification applied for absolute quantification of nucleic acids by digital droplet RPA.

Aqueous microdroplets provide miniaturized reaction compartments for numerous chemical, biochemical or pharmaceutical applications. We introduce centrifugal step emulsification for the fast and easy production of monodisperse droplets. Homogenous droplets with pre-selectable diameters in a range from 120 μm to 170 μm were generated with coefficients of variation of 2-4% and zero run-in time or ...

متن کامل

O-5: Preparation of Multi-Component Drug Delivery Systems

Background: Despite global interest, the development of single step processes for the preparation of effective drug delivery systems still faces numerous challenges. There is great demand for processing methods that are efficient, flexible, scalable and economical for the generation of wide range of encapsulated structures. Over the past few decades, electrohydrodynamic (EHD) processing has rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 9 20  شماره 

صفحات  -

تاریخ انتشار 2009