Rapid measurement of creatine kinase activity in a coronary care unit using a portable benchtop reflectance photometer.

نویسندگان

  • I Gibb
  • J R Barton
  • P C Adams
  • D Pratt
  • C R Dean
  • I F Tarbit
چکیده

Rapid measurements of plasma creatine kinase activity using an inexpensive benchtop reflectance photometer (Ames Seralyzer) and disposable reagent strips were evaluated in the laboratory and coronary care unit. The system proved simple to use and capable of yielding rapid (four minutes per analysis), precise (coefficient of variation less than 9%), and accurate results (correlation with routine method 0.995) when used by medical staff. Creatine kinase values were available 6.5-102 hours earlier than routine laboratory data, depending on the time and day of sampling, thereby facilitating appropriate and economic patient management. This instrument might be used to supplement the routine enzyme service for selected admissions, resulting in greatly improved availability of results and hence contributing to the early discharge of patients from intensive care facilities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the value of novel rapid measurement of myoglobin, creatine kinase, and creatine kinase-MB with the electrocardiogram for the diagnosis of acute myocardial infarction.

OBJECTIVE To determine whether serum myoglobin, creatine kinase, and creatine kinase-MB measured at admission by rapid, compact, and easy to use automated quantitative analysers (results within 10 min) helped the early identification of acute myocardial infarction. The results were compared with the data obtained from the electrocardiograms recorded at admission. DESIGN A prospective study. ...

متن کامل

Diagnosis of acute myocardial infarction from sequential enzyme measurements obtained within 12 hours of admission to hospital.

A prospective study was made of sequential changes in serum creatine kinase (CK) and CK-MB isoenzyme activity within the 12 hours following admission to the coronary care unit on 65 patients with recent chest pain. CK determinations were performed in the laboratory or in the coronary care unit using a dry reagent strip analyser. Slope values for log CK/hour and log CK-MB/hour were calculated, u...

متن کامل

Comparison of pregnancy-associated plasma protein-A, troponin and creatine kinase-MB levels in acute coronary syndrome

Background: Early diagnosis and proper treatment of patient with acute coronary syndrome (ACS) and ischemic heart disease are important in determining prognosis, preventing adverse effects, and may even save lives. In this study, the level of pregnancy-associated plasma protein-A (PAPP-A) in ACS patients was compared with the control group, in addition to cardiac Troponin (cTn) and creatine kin...

متن کامل

مقایسه‌ی نتایج استفاده از شانت داخل عروق کرونر در عمل بای‌پس عروق کرونر بدون پمپ نسبت به عدم استفاده از آن

Background and Objective: Off pump coronary artery bypass graft can be done with or without using intracoronary shunt. We have compared these two methods in early postoperative period, in this study. Materials and Methods: 208 candidate patients for off pump coronary artery bypass graft were devided in to two groups randomly for using intracoronary shunt or not. Variables including peri and pos...

متن کامل

In Vitro Inhibition of Human Sperm Creatine Kinase by Nicotine, Cotinine and Cadmium, as a Mechanism in Smoker Men Infertility

Background Nicotine, cotinine and cadmium are harmful components of cigarettes that have an effect on human reproductive function. Although the effects of cigarette smoke on male reproductive function is characterized in several articles its mechanism of action is still unknown. In the present study, we investigate the effect of nicotine, cotinine and cadmium on human sperm creatine kinase acti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British medical journal

دوره 290 6479  شماره 

صفحات  -

تاریخ انتشار 1985