Sandwich enzyme immunoassay of osteocalcin in serum with use of an antibody against human osteocalcin.

نویسندگان

  • D A Monaghan
  • M J Power
  • P F Fottrell
چکیده

We have developed and thoroughly validated a solid-phase sandwich enzyme-linked immunosorbent assay (ELISA) on microtiter plates for osteocalcin in human serum with use of an antibody raised against human osteocalcin. We used a monoclonal antibody against bovine osteocalcin as the capture antibody; the second antibody was a polyclonal antibody against human osteocalcin. The amount of bound second antibody was determined with use of swine anti-rabbit antibody labeled with horseradish peroxidase. We demonstrated independence of volume and determined the recovery of added standard and within- and between-assay precision. The minimal detection limit for osteocalcin was between 1.0 and 1.5 micrograms/L and the midpoint of the standard curve ranged from 14 to 17 micrograms/L. The intraassay CV was < or = 8% in the range 2.7-52 micrograms/L; the interassay CV was usually < or = 15% in the same range. Analytical recovery of human osteocalcin standard added to serum samples was consistently > 90%. Values for osteocalcin measured in serum from 44 normal subjects were similar to those obtained with a competitive enzyme immunoassay (EIA) that used a monoclonal antibody against bovine osteocalcin. There was a good correlation between the two assays [r2 = 0.877, slope and intercept (+/- SE) = 0.88(+/- 0.051) and 0.316(+/- 0.523), respectively]. The range and mean (+/- SD) for the sandwich ELISA and the competitive EIA were 1.7-18.1 micrograms/L [8.7(+/- 4.4) micrograms/L] and 1.9-22.8 micrograms/L [9.1(+/- 4.4) micrograms/L], respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Avidin-biotin enzyme immunoassay of osteocalcin in serum or plasma.

We describe a competitive enzyme immunoassay, the ExtrAvidin-biotin system, for determining osteocalcin in human serum or plasma. Antibodies were raised against bovine osteocalcin. Binding of the antibodies to osteocalcin was calcium-dependent. Limit of detection is 0.07 nmol/L (0.4 microgram/L). The standard curve for method is linear between 0.3 and 17.6 nmol/L (1.9 and 100 micrograms/L). Int...

متن کامل

Evaluation of a bead-based enzyme immunoassay for the rapid detection of osteocalcin in human serum.

BACKGROUND Circulating osteocalcin is a well-known marker for bone formation, but none of the commercial kits currently available can be used in automated systems. Here we present the first semiautomated assay for human serum osteocalcin. METHODS Polystyrene beads were coated with antibodies against the COOH terminus of osteocalcin and used in the COBAS((R)) EIA System. Osteocalcin was detect...

متن کامل

Solid-phase enzymoimmunoassay for osteocalcin in human serum or plasma, with use of a monoclonal antibody.

In this solid-phase enzymoimmunoassay on microtiter plates for osteocalcin in serum or plasma, we use an osteocalcin-horseradish-peroxidase conjugate and a monoclonal antibody raised against bovine osteocalcin. We thoroughly standardized the assay for measurement of osteocalcin in both serum and plasma, demonstrating independence of sample volume, and determining the analytical recovery and wit...

متن کامل

Effects of Oral Dosage of Lead Acetate II on Osteocalcin Gene Expression in Rat Mesenchymal Stem Cells

Background: Lead (Pb) is a heavy metal that has devastating effects on many animal tissues. In this study we investigated the effects of orally-dosed lead acetate II on osteocalcin gene (osteocalcin) expression in mesenchymal stem cells grown in an osteogenic medium. Osteocalcin is an abundant bone matrix differentiation protein. Methods: Twelve male Wistar rats were divided into three groups ...

متن کامل

Serum osteocalcin is associated with measures of insulin resistance, adipokine levels, and the presence of metabolic syndrome.

OBJECTIVE Osteocalcin has been reported to influence insulin secretion in experimental animals. We investigated whether serum osteocalcin was associated with measures of insulin resistance, circulating adipokine levels, and the presence of metabolic syndrome (MetSyn). METHODS AND RESULTS Serum osteocalcin was measured by solid-phase sandwich immunoassay in 1284 blacks (64+/-9 years; 71% women...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 6  شماره 

صفحات  -

تاریخ انتشار 1993