Evaluation of Ocular Biomechanical Indices to Distinguish Normal from Keratoconus Eyes

نویسندگان

  • Allan Luz
  • Bruno Fontes
  • Isaac C Ramos
  • Bernardo Lopes
  • Fernando Correia
  • Paulo Schor
  • Renato Ambrósio
چکیده

Purpose: To compare and assess the ability of pressure-derived parameters and corneal deformation waveform signal-derived parameters of the ocular response analyzer (ORA) measurement to distinguish between keratoconus and normal eyes, and to develop a combined parameter to optimize the diagnosis of keratoconus. Materials and methods: One hundred and seventy-seven eyes (177 patients) with keratoconus (group KC) and 205 normal eyes (205 patients; group N) were included. One eye from each subject was randomly selected for analysis. Patients underwent a complete clinical eye examination, corneal topography (Humphrey ATLAS), tomography (Pentacam Oculus) and biomechanical evaluations (ORA Reichert). Differences in the distributions between the groups were assessed using the MannWhitney test. The receiver operating characteristic (ROC) curve was used to identify cutoff points that maximized sensitivity and specificity in discriminating keratoconus from normal corneas. Logistic regression was used to identify a combined linear model (Fisher 1.0). Results: Significant differences in all studied parameters were detected (p < 0.05), except for W2. For the corneal resistance factor (CRF): Area under the ROC curve (AUROC) 89.1%, sensitivity 81.36%, specificity 84.88%. For the p1area: AUROC 91.5%, sensitivity 87.1%, specificity 81.95%. Of the individual parameters, the highest predictive accuracy was for the Fisher 1.0, which represents the combination of all parameters (AUROC 95.5%, sensitivity 88.14%, specificity 93.17%). Conclusion: Waveform-derived ORA parameters displayed greater accuracy than pressure-derived parameters for identifying keratoconus. Corneal hysteresis (CH) and CRF, a diagnostic linear model that combines different parameters, provided the greatest accuracy for differentiating keratoconus from normal corneas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ویژگی‌های بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری

Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...

متن کامل

Multivariate Analysis of the Ocular Response Analyzer's Corneal Deformation Response Curve for Early Keratoconus Detection

Purpose. To thoroughly analyze corneal deformation responses curves obtained by Ocular Response Analyzer (ORA) testing in order to improve subclinical keratoconus detection. Methods. Observational case series of 87 control and 73 subclinical keratoconus eyes. Examination included corneal topography, tomography, and biomechanical testing with ORA. Factor analysis, logistic regression, and receiv...

متن کامل

ORA waveform-derived biomechanical parameters to distinguish normal from keratoconic eyes.

PURPOSE To evaluate the ability of the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) to distinguish between normal and keratoconic eyes, by comparing pressure and waveform signal-derived parameters. METHODS This retrospective comparative case series study included 112 patients with normal corneas and 41 patients with bilateral keratoconic eyes. One eye from each...

متن کامل

Complementary Keratoconus Indices Based on Topographical Interpretation of Biomechanical Waveform Parameters: A Supplement to Established Keratoconus Indices

Purpose. To build new models with the Ocular Response Analyzer (ORA) waveform parameters to create new indices analogous to established topographic keratoconus indices. Method. Biomechanical, tomographic, and topographic measurements of 505 eyes from the Homburger Keratoconus Centre were included. Thirty-seven waveform parameters (WF) were derived from the biomechanical measurement with the ORA...

متن کامل

Differentiating Keratoconus and Corneal Warpage by Analyzing Focal Change Patterns in Corneal Topography, Pachymetry, and Epithelial Thickness Maps

PURPOSE To differentiate between keratoconus and contact lens-related corneal warpage by combining focal change patterns in anterior corneal topography, pachymetry, and epithelial thickness maps. METHODS Pachymetry and epithelial thickness maps of normal, keratoconus, and warpage, and forme fruste keratoconus (FFK) eyes were obtained from a Fourier-domain optical coherence tomography (OCT). E...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013