Automated detection and cell density assessment of keratocytes in the human corneal stroma from ultrahigh resolution optical coherence tomograms
نویسندگان
چکیده
Keratocytes are fibroblast-like cells that maintain the optical clarity and the overall health of the cornea. The ability to measure precisely their density and spatial distribution in the cornea is important for the understanding of corneal healing processes and the diagnostics of some corneal disorders. A novel computerized approach to detection and counting of keratocyte cells from ultra high resolution optical coherence tomography (UHR-OCT) images of the human corneal stroma is presented. The corneal OCT data is first processed using a state-of-the-art despeckling algorithm to reduce the effect of speckle on detection accuracy. A thresholding strategy is then employed to allow for improved delineation of keratocyte cells by suppressing similarly shaped features in the data, followed by a second-order moment analysis to identify potential cell nuclei candidates. Finally, a local extrema strategy is used to refine the candidates to determine the locations and the number of keratocyte cells. Cell density distribution analysis was carried in 3D UHR-OCT images of the human corneal stroma, acquired in-vivo. The cell density results obtained using the proposed novel approach correlate well with previous work on computerized keratocyte cell counting from confocal microscopy images of human cornea.
منابع مشابه
Evaluation of hypoxic swelling of human cornea with high speed, ultrahigh resolution optical coherence tomography
Hypoxia induced corneal swelling was observed and evaluated in healthy human volunteers by use of high speed, ultrahigh resolution optical coherence tomography (UHROCT). Two dimensional corneal images were acquired at a speed of 47,000 A-scans/s with 3μm x 10μm (axial x lateral) resolution in corneal tissue. The UHROCT tomograms showed clear visualization of all corneal layers, including the Bo...
متن کاملCorneal Stroma Regeneration with Acellular Corneal Stroma Sheets and Keratocytes in a Rabbit Model
Acellular corneal stroma matrix has been used for corneal stroma engineering. However, because of its compact tissue structure, regrowth of keratocytes into the scaffold is difficult. Previously, we developed a sandwich model for cartilage engineering using acellular cartilage sheets. In the present study, we tested this model for corneal stroma regeneration using acellular porcine corneal stro...
متن کاملHistologic correlation of pig retina radial stratification with ultrahigh-resolution optical coherence tomography.
PURPOSE To compare ultrahigh-resolution optical coherence tomography (OCT) cross-sectional images of the pig retina with histology, to evaluate the potential of ultrahigh-resolution OCT for enhanced visualization of intra- and subretinal structures. METHODS Ultrahigh-resolution OCT images were acquired with 1.4- micro m axial x 3- micro m transverse resolution from in vitro posterior eyecup p...
متن کاملInvolvement of C-C chemokine ligand 2-CCR2 interaction in monocyte-lineage cell recruitment of normal human corneal stroma.
Bone marrow-derived cells (BMCs) reside in the anterior stroma of the central and paracentral cornea, as well as all stromal layers of the peripheral cornea, in normal human eyes. We investigated the factors regulating the constitutive distribution of BMCs in normal human corneal stroma. Cultured human corneal keratocytes expressed several chemokines (growth-related oncogene/CXCL1-3, IL-8/CXCL8...
متن کاملFractal analysis for classification of breast carcinoma in optical coherence tomography.
The accurate and rapid assessment of tumor margins during breast cancer resection using optical coherence tomography (OCT) has the potential to reduce patient risk. However, it is difficult to subjectively distinguish cancer from normal fibroglandular stromal tissues in OCT images, and an objective measure is needed. In this initial study, we investigate the potential of a one-dimensional fract...
متن کامل