Heterogeneous enzyme immunoassay of alpha-fetoprotein in maternal serum by flow-injection amperometric detection of 4-aminophenol.

نویسندگان

  • Y Xu
  • B Halsall
  • W R Heineman
چکیده

A sandwich-type heterogeneous enzyme immunoassay with flow-injection analysis for alpha-fetoprotein (AFP) in human serum has been developed. 4-Aminophenol, the product of enzymatic reaction, is detected amperometrically. The interassay CV for this electrochemical enzyme immunoassay was less than 8.2%, with a minimum detection limit for AFP of 0.163 micrograms/L. The calibration curve had a linear range of 0.316-100 micrograms/L. Studies with 48 human maternal serum samples, comparing results by this method with those by a commercial kit, showed a good correlation (r = 0.961). This procedure provides an alternative method for determining low concentrations of AFP in human maternal serum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Competitive heterogeneous enzyme immunoassay for theophylline by flow-injection analysis with electrochemical detection of p-aminophenol.

A competitive enzyme-linked immunoabsorbent assay based on the flow-injection amperometric detection of p-aminophenol has been investigated with use of the materials and general procedure of a commercial kit for the determination of theophylline in human serum. The antibody is immobilized on glass beads, and the enzyme label is alkaline phosphatase (EC 3.1.3.1). The high currents generated duri...

متن کامل

A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers.

BACKGROUND Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. METHODS We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetopr...

متن کامل

بررسی ارتباط سطح سرمی آلفا فتوپروتئین مادری در هفته های یازدهم تا سیزدهم بارداری و زایمان پره ترم در مادران باردار

Background: Preterm labor is considered one of the major health concerns and seconds congenital anomalies for infant morbidity and mortality. So far, various methods have been used to predict preterm labor; one of these methods is to measure mother’s serum alpha-fetoprotein level. This study was conducted to investigate the relationship between maternal serum alpha-fetoprotein level in we...

متن کامل

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

Status of serum alpha feto-protein (AFP) and midkine (MDK) levels in patients with hepatocellular carcinoma

Introduction: Hepatocellular carcinoma (HCC) is sixth common cancers worldwide and predominant in Asia and Africa. A number of evidence suggests a possible role of midkine (MDK) and α-fetoprotein (AFP) in the pathogenesis of hepatocellular carcinoma (HCC). Materials and methods: We studied MDK and AFP in patients with HCC or in healthy controls. MDK and AFP was measured by enzyme linked immuno...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 36 11  شماره 

صفحات  -

تاریخ انتشار 1990