Microsoft Point-To-Point Compression (MPPC) Protocol
نویسنده
چکیده
Status of this Memo This memo provides information for the Internet community. This memo does not specify an Internet standard of any kind. Distribution of this memo is unlimited. Abstract The Point-to-Point Protocol (PPP) [1] provides a standard method for transporting multi-protocol datagrams over point-to-point links. The PPP Compression Control Protocol [2] provides a method to negotiate and utilize compression protocols over PPP encapsulated links. This document describes the use of the Microsoft Point to Point Compression protocol (also referred to as MPPC in this document) for compressing PPP encapsulated packets.
منابع مشابه
Application of Hamamatsu MPPC to T2K Neutrino Detectors
A special type of Hamamatsu MPPC, with a sensitive area of 1.3×1.3 mm containing 667 pixels with 50×50 μm each, has been developed for the near neutrino detector in the T2K long baseline neutrino experiment. About 60 000 MPPCs will be used in total to read out the plastic scintillator detectors with wavelength shifting fibers. We report on the basic performance of MPPCs produced for T2K.
متن کاملMass production test of Hamamatsu MPPC for T2K neutrino oscillation experiment
In the T2K near neutrino detectors, about 60 000 Hamamatsu Multi-Pixel Photon Counters (MPPCs) will be used. The mass production of MPPC has started in February 2008. In order to perform quality assurance and to characterize each device, we have developed an MPPC test system. For each MPPC, gain, breakdown voltage, noise rate, photo detection efficiency, and cross-talk and after-pulse rate are ...
متن کاملTarget Design and R&D of J-PARC E06 TREK experiment
TREK is an experiment to search for violation of time reversal invariance (T-violation) in the kaon decay of K π0μ ν planned at the Japan Proton Accelerator Research Complex (J-PARC). The active target is one of the primal detector elements of the TREK detector system. Kaons come from the beam line, stop and decay in the target. The active target consists of a bundle of scintillating fiber and ...
متن کاملDirectly Coupled Tiles as Elements of a Scintillator Calorimeter with MPPC Readout
We present results on the direct i.e. fiberless coupling of scintillator tiles to Multipixel Photon Counters (MPPC). The fiberless option has the potential of simplifying the assembly and construction of a finely-segmented scintillator-based calorimeter with MPPC readout. In this paper we show detailed studies on the response and uniformity of directly coupled tiles and describe our concept for...
متن کاملUtilizing light-triggered plasmon-driven catalysis reactions as a template for molecular delivery and release† †Electronic supplementary information (ESI) available: 1H NMR, 13C NMR, and mass spectrum information of synthesized MPPC molecule, the mass spectra of supernatant solution subject to 0 and 180 min of laser irradiation, calibration curve of PyA concentration vs. fluorescence intensity at 381 nm, and the extinction spectrum of the AuNPs. See DOI: 10.1039/c7sc02089a Click here for additional data file.
متن کامل
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- RFC
دوره 2118 شماره
صفحات -
تاریخ انتشار 1997