Negative lens concept for photoacoustic tomography.

نویسندگان

  • Changhui Li
  • Geng Ku
  • Lihong V Wang
چکیده

Although a small point ultrasound transducer has a wide acceptance angle, its small active area leads to a high thermal-noise-induced electric voltage in the transducer, thus the sensitivity is low. By contrast, a finite-size flat transducer has high sensitivity, but the acceptance angle is small, which limits its application in reconstruction-based photoacoustic tomography (PAT). Here, we propose a negative lens concept to increase the acceptance angle of a flat transducer without losing sensitivity. Phantom experiments demonstrate that use of this concept greatly increases the detection region for PAT with high sensitivity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tangential resolution improvement in thermoacoustic and photoacoustic tomography using a negative acoustic lens.

We developed a novel concept of using a negative acoustic lens to increase the acceptance angle of an unfocused large-area ultrasonic transducer (detector), leading to more than twofold improvement of the tangential resolution in both thermoacoustic and photoacoustic tomography. In both thermoacoustic and photoacoustic tomography, for a given transducer bandwidth, the aperture size of the detec...

متن کامل

A new acoustic lens material for large area detectors in photoacoustic breast tomography☆

OBJECTIVES We introduce a new acoustic lens material for photoacoustic tomography (PAT) to improve lateral resolution while possessing excellent acoustic acoustic impedance matching with tissue to minimize lens induced image artifacts. BACKGROUND A large surface area detector due to its high sensitivity is preferable to detect weak signals in photoacoustic mammography. The lateral resolution ...

متن کامل

Photoacoustic imaging in biomedicine

Photoacoustic imaging also called optoacoustic or thermoacoustic imaging has the potential to image animal or human organs, such as the breast and the brain, with simultaneous high contrast and high spatial resolution. This article provides an overview of the rapidly expanding field of photoacoustic imaging for biomedical applications. Imaging techniques, including depth profiling in layered me...

متن کامل

Improving tangential resolution with a modified delay-and-sum reconstruction algorithm in photoacoustic and thermoacoustic tomography.

Spatial resolution in photoacoustic and thermoacoustic tomography is ultrasound transducer (detector) bandwidth limited. For a circular scanning geometry the axial (radial) resolution is not affected by the detector aperture, but the tangential (lateral) resolution is highly dependent on the aperture size, and it is also spatially varying (depending on the location relative to the scanning cent...

متن کامل

Simultaneous photoacoustic imaging technique using an acoustic imaging lens.

A simultaneous photoacoustic (PA) tomography imaging technique in multilayer samples was developed. Instead of using the PA image reconstruction methods on the basis of complex algorithms, obtaining a two-dimensional PA image in real time is available by using an acoustic lens that has the ability of parallel imaging. The imaging system can acquire the complete PA signals of high signal-to-nois...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review. E, Statistical, nonlinear, and soft matter physics

دوره 78 2 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2008