Oxidation markedly reduces bilirubin interference in the Jaffé creatinine assay.
نویسندگان
چکیده
Bilirubin causes underestimation of serum creatinine in the Jaffé alkaline picrate assay. We report an approach for preventing bilirubin interference by pretreating serum samples with peroxidase and H2O2. The dissociation of bilirubin from albumin and its subsequent oxidation markedly reduces the bilirubin interference and enables accurate determination of creatinine concentrations by the Jaffé reaction even in hyperbilirubinemic sera. Within-run CVs were 2.6%, 4.0%, and 3.8% at mean creatinine concentrations of 88, 165, and 349 mumol/L, respectively (n = 20). Day-to-day CVs were 4.0%, 6.3%, and 5.8% for mean creatinine concentrations of 87, 168, and 364 mumol/L, respectively (n = 12). Average recovery of creatinine added to serum in the presence of 600 mumol/L bilirubin was 97% (n = 15). This method requires only small serum volumes (70 microL) and is easily applicable to automated analyzers that can be programmed to add three reagents consecutively.
منابع مشابه
A simplified procedure for eliminating the negative interference of bilirubin in the Jaffé reaction for creatinine.
The negative interference by bilirubin in the measurement of creatinine by the Jaffé procedure is well documented. We describe a procedure for the elimination of interfering bilirubin by oxidation to biliverdin through the addition of potassium ferricyanide before the alkaline picrate reagent. We detected no negative interference with the addition of as much as 600 mumol/L bilirubin. The proced...
متن کاملA solution to the problem of bilirubin interference with the kinetic Jaffé method for serum creatinine.
We measured bilirubin interference with the kinetic Jaffé method for serum creatinine. Both pooled sera with added bilirubin and icteric patients' sera were used and results with of which gave more nearly "true" values.
متن کاملInterferences in current methods for measurements of creatinine.
We measured the interference of carbonyl compounds, drugs, and other substances in human serum on the determination of creatinine by the two-point, fixed-time kinetic modification of the Jaffé reaction as well as by four enzymatic methods. We added known concentrations of the interfering substances to a solution of creatinine in water. For bilirubin, we used both pooled normal sera with added b...
متن کاملEvaluation of an enzymatic method for determining creatinine in plasma.
An enzymatic kit method for the determination of plasma creatinine was optimised for use with a centrifugal analyser and its performance characteristics and practicability compared with an end point and a kinetic Jaffé-based method. The enzymatic method exhibited several advantages over Jaffé-based methods--namely, smaller sample size, rapid sample throughput (200 per hour), and improved specif...
متن کاملKinetic serum creatinine assays. II. A critical evaluation and review.
We have evaluated the Technicon AutoAnalyzer method, the Beckman Creatinine Analyzer II, DuPont aca, Electro-Nucleonics GEMSAEC, and Instrumentation Laboratory Model 916 kinetic methods for determination of serum creatinine. These methods, which involve the Jaffé reaction, all showed a statistically significant proportional error relative to an ion-exchange pretreatment method for creatinine in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 38 12 شماره
صفحات -
تاریخ انتشار 1992