In order to test if the rate of onset of sensation of warmth in the legs after the injection of 0.5% bupivacaine might discriminate between subarachnoid and extradural injection, 150 urological patients were allocated randomly to receive either spinal anaesthesia with isobaric (IS) or hyperbaric (HS) 0.5% bupivacaine, or extradural anaesthesia with isobaric 0.5% bupivacaine. The volume of the local anaesthetic for spinal anaesthesia and for the extradural test dose was 3-4 ml. The patients were asked to report at once if they had a sensation of warmth in the legs during or after injection of local anaesthetic. The mean time to the sensation of warmth was significantly shorter in the spinal groups (80 (SEM 10) s in IS and 76 (8.0) s in HS) than in the extradural group (558 (38) s). However, six patients in the IS and two in the HS group had no sensation of warmth.
منابع مشابه
Comparison of Flurochrome , Ziehl-Neelsen and Tan Thiam Hok Staining Methods for Detection of Mycobacterium tuberculosis in Sputums of Patients with Pulmonary Tuberculosis
Abstract Background and objectives: Direct smear microscopy, because of its simplicity, rapidity, low cost and relatively sensitive is a suitable method to detecting pulmonary tuberculosis. This experiment was aimed at determining the best method for detecting Mycobacterium tuberculosis among three kinds of staining methods: Fluorochrome, Ziehl Neelsen and Tan Thiam Hok . Material and Methods: ...
متن کاملارزش تشخیصی -MSCT آنژیوگرافی با تکنولوژی 64 - Sliceدر مقایسه با آنژیوگرافی مرسوم در شناسایی بیماری شریان کرونری
Background: Multislice computed tomography (MSCT) is a noninvasive method of detecting coronary artery disease (CAD). The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64-MSCT) in daily practice, without patient selection. Methods: Sixty-four consecutive suspected CAD patients underwent both 64-MSCT and quantitative coronary angiography (QCA). The CT system The...
متن کاملCompare of Sensitivity and Specificity of Liquid-Based and Conventional Cytology Smears in Fine Needle Aspirates for Diagnosis of Breast Mass
Introduction: This study aimed to compare the cytology results obtained by the conventional smear method with those obtained by the liquid-based method for the diagnosis of palpable breast masses in women referred to the clinic of Shahid Mohammadi Hospital in Bandar Abbas city. Methods: The research method was descriptive–cross-sectional. The research sample was selected based on purposive and ...
متن کاملRopivacaine test dose in extradural anaesthesia.
Ropivacaine test dose in extradural anaesthesia Morton and colleagues 1 have described the use of 0.75% ropiva-caine for extradural anaesthesia, and in the process have clearly demonstrated the unsuitability of this agent as a test dose. The aim of an extradural test dose is to identify inadvertent i.v. or intrathecal catheter placement. It should have high sensitivity, but produce symptoms tha...
متن کاملHow valid is the tallquist method in screening pregnant women with anemia in poor rural settings of southwestern Nigeria?
Background: Diagnosis of anemia is challenging in resource-poor settings due to inadequate laboratory resources. This study assessed the validity of the Tallquist haemoglobinometer in assessing anemia among pregnant women in Osogbo, Southwestern Nigeria. Methods: This was a cross - sectional study, in which 200 pregnant women of reproductive age were selected using multist...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 66 5 شماره
صفحات -
تاریخ انتشار 1991