New implant for drainage in glaucoma. Clinical trial.

نویسنده

  • A C Molteno
چکیده

(2) A thin acrylic plate is rigidly attached to this tube in such a way that the lumen of the tube opens onto the upper surface of the plate. This plate (8 mm. in diameter and approximately circular in outline) is curved to fit and firmly sutured to the sclera. When covered by a flap of conjunctiva and Tenon's capsule, the plate forms the floor of a blel) wvhich is in free communication with the anter-ior chamber aild cannot shrink to an area less than that of the plate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective Comparison of Intermediate-term Efficacy of 350 mm2 Glaucoma Drainage Implants and Medium-sized 230-250 mm2 Implants

AIM To compare the intermediate-term efficacy of a large surface area Baerveldt 350 mm2 glaucoma drainage device (GDD) with medium surface area implants (Baerveldt 250 mm2 and Molteno 3, 230, or 245 mm2). DESIGN This is a retrospective, nonrandomized comparative trial. MATERIALS AND METHODS A total of 94 eyes of 94 patients of mixed glaucoma diagnoses without any prior glaucoma surgical pro...

متن کامل

Glaucoma drainage implants: a critical comparison of types.

PURPOSE OF REVIEW The purpose of this review is to critically compare the various glaucoma drainage implants in popular use. RECENT FINDINGS Glaucoma drainage implants are being increasingly utilized in the surgical management of glaucoma. Comparisons between the various drainage implants are difficult because most clinical data are derived from retrospective studies with different study popu...

متن کامل

Five-year treatment outcomes in the Ahmed Baerveldt comparison study.

PURPOSE To compare the 5-year outcomes of the Ahmed FP7 Glaucoma Valve (AGV) (New World Medical, Cucamonga, CA) and the Baerveldt 101-350 Glaucoma Implant (BGI) (Abbott Medical Optics, Abbott Park, IL) for the treatment of refractory glaucoma. DESIGN Multicenter, randomized, controlled clinical trial. PARTICIPANTS A total of 276 patients, including 143 in the AGV group and 133 in the BGI gr...

متن کامل

Plain film imaging of Baerveldt glaucoma drainage implants.

A glaucoma drainage implant was detected on plain skull radiographs before MR imaging examination of the brain. The patient was denied the MR imaging for fear of dislodging the "metallic foreign body." The Baerveldt glaucoma drainage implant was mistakenly identified as an orbital metallic object based on its radiographic characteristics. Because none of the current glaucoma drainage implants c...

متن کامل

New implant for drainage in glaucoma. Animal trial.

The implant described in this communication is the direct descendent of a long series of artificial drainage devices which began when Zorab (I9I2) inserted a silk thread through the limbus in order to drain aqueous into the subconjunctival space in cases of glaucoma (see also Mayou, I9I2). Among the more recently described devices are teflon drainage tubes in man (Richards, I955; Epstein, 1959;...

متن کامل

A novel flexible microfluidic meshwork to reduce fibrosis in glaucoma surgery

PURPOSE/RELEVANCE Fibrosis and hence capsule formation around the glaucoma implants are the main reasons for glaucoma implant failure. To address these issues, we designed a microfluidic meshwork and tested its biocompatibility in a rabbit eye model. The amount of fibrosis elicited by the microfluidic meshwork was compared to the amount elicited by the plate of conventional glaucoma drainage de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 53 9  شماره 

صفحات  -

تاریخ انتشار 1969