Reliability of readings of magnetic resonance imaging features of lumbar spinal stenosis.

نویسندگان

  • Jon D Lurie
  • Anna N Tosteson
  • Tor D Tosteson
  • Eugene Carragee
  • John A Carrino
  • Jay Kaiser
  • Roberto T Blanco Sequeiros
  • Amy Rosen Lecomte
  • Margaret R Grove
  • Emily A Blood
  • Loretta H Pearson
  • James N Weinstein
  • Richard Herzog
چکیده

STUDY DESIGN A reliability assessment of standardized magnetic resonance imaging (MRI) interpretations and measurements. OBJECTIVE To determine the intra- and inter-reader reliability of MRI features of lumbar spinal stenosis (SPS), including severity of central, subarticular, and foraminal stenoses, grading of nerve root impingement, and measurements of cross-sectional area of the spinal canal and thecal sac. SUMMARY OF BACKGROUND DATA MRI is commonly used to assess patients with spinal stenosis. Although a number of studies have evaluated the reliability of certain MRI characteristics, comprehensive evaluation of the reliability of MRI readings in spinal stenosis is lacking. METHODS Fifty-eight randomly selected MR images from patients with SPS enrolled in the Spine Patient Outcomes Research Trial were evaluated. Qualitative ratings of imaging features were performed according to defined criteria by 4 independent readers (3 radiologists and 1 orthopedic surgeon). A sample of 20 MRIs was reevaluated by each reader at least 1 month later. Weighted kappa statistics were used to characterize intra- and inter-reader reliability for qualitative rating data. Separate quantitative measurements were performed by 2 other radiologists. Intraclass correlation coefficients and summaries of measurement error were used to characterize reliability for quantitative measurements. RESULTS Intra-reader reliability was higher than inter-reader reliability for all features. Inter-reader reliability in assessing central stenosis was substantial, with an overall kappa of 0.73 (95% CI 0.69-0.77). Foraminal stenosis and nerve root impingement showed moderate to substantial agreement with overall kappa of 0.58 (95% CI 0.53-0.63) and 0.51 (95% CI 0.42-0.59), respectively. Subarticular zone stenosis yielded the poorest agreement (overall kappa 0.49; 95% CI 0.42-0.55) and showed marked variability in agreement between reader pairs. Quantitative measures showed inter-reader intraclass correlation coefficients ranging from 0.58 to 0.90. The mean absolute difference between readers in measured thecal sac area was 128 mm (13%). CONCLUSION The imaging characteristics of spinal stenosis assessed in this study showed moderate to substantial reliability; future studies should assess whether these findings have prognostic significance in SPS patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verification of measurements of lumbar spinal dimensions in T1- and T2-weighted magnetic resonance imaging sequences.

BACKGROUND CONTEXT Magnetic resonance imaging (MRI) is commonly used to assess patients with lumbar spinal stenosis. No single MRI sequence has been shown to be superior in spinal canal measurements. There are also cost concerns for the increased clinical and research use of MRI. Using only a single sequence may lower the financial burden; however, this requires spinal canal measurements in bot...

متن کامل

Inter- and Intraobserver Agreement of Morphological Grading for Central Lumbar Spinal Stenosis on Magnetic Resonance Imaging

Study Design Validation study of a morphological grading system for central lumbar spinal stenosis. Objective To evaluate and validate the inter- and intraobserver agreement of a morphological grading system for central lumbar spinal stenosis on magnetic resonance imaging between neurosurgeons and radiologists. Methods Two neurosurgeons and two radiologists independently assessed the morphologi...

متن کامل

Reliability and Validity of the Swiss Spinal Stenosis Questionnaire for Iranian Patients with Lumbar Spinal Stenosis

Background: The purpose of this study was validation of the Persian translation of the Swiss Spinal StenosisQuestionnaire in order to be used by Iranian researchers.Methods: A total of 104 patients with spinal stenosis diagnosis, who were candidates for operative treatment wereentered into the study. The patients completed the translated questionnaire in the 1st and the 7th days of admissionand...

متن کامل

Reliability of magnetic resonance imaging readings for lumbar disc herniation in the Spine Patient Outcomes Research Trial (SPORT).

STUDY DESIGN Assessment of the reliability of standardized magnetic resonance imaging (MRI) interpretations and measurements. OBJECTIVE To determine the intra- and inter-reader reliability of MRI parameters relevant to patients with intervertebral disc herniation (IDH), including disc morphology classification, degree of thecal sac compromise, grading of nerve root impingement, and measuremen...

متن کامل

Assessment of magnetic resonance imaging in the diagnosis of lumbar spine foraminal stenosis--a surgeon's perspective.

STUDY DESIGN A 2-part cadaveric study. OBJECTIVES Part 1: To assess the reliability of a semiquantitative classification system for grading lumbar spine foraminal stenosis and the variability in magnetic resonance imaging (MRI) examinations carried out in different institutions. Part 2: to assess the difference between the foraminal measurements carried out on MRI images and on cadaveric spec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 33 14  شماره 

صفحات  -

تاریخ انتشار 2008