An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty.
نویسندگان
چکیده
STUDY DESIGN Comparative ex vivo biomechanical study. OBJECTIVE To determine the strength and stiffness of osteoporotic vertebral bodies subjected to compression fractures and stabilized via bipedicular injections of the following: 1) Simplex P (Stryker-Howmedica-Osteonics, Rutherford, NJ), 2) Simplex P formulated consistent with the practice of vertebroplasty (F2), or 3) BoneSource (Stryker-Howmedica-Osteonics). SUMMARY OF BACKGROUND DATA Little is known about the mechanical stabilization afforded by new materials proposed for use with vertebroplasty. METHODS Vertebral bodies (T8-T10 and L2-L4) from each of 10 fresh spines were harvested from female cadavers (81 +/- 12 years), screened for bone density (t score, -3.8 +/- 1.1; bone mineral density, 0.75 +/- 15 g/cm2), disarticulated, and compressed to determine initial strength and stiffness. The fractured vertebral bodies were stabilized via bipedicular injections of 4 mL (thoracic) or 6 mL (lumbar) and then recrushed. RESULTS Vertebral bodies repaired with Simplex P resulted in significantly greater strength (P < 0.05) relative to their prefracture states, those repaired with BoneSource resulted in the restoration of initial strength for both the thoracic and lumbar level, and those repaired with F2 resulted in significantly greater strength (P < 0.05) in the thoracic region and restoration of strength in the lumbar region. All cement treatments resulted in significantly less stiffness compared with initial values. CONCLUSIONS All three materials tested restored or increased vertebral body strength, but none restored stiffness. Both new materials show promise for use in percutaneous vertebroplasty, but they need clinical evaluation.
منابع مشابه
An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture.
STUDY DESIGN Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. OBJECTIVES To determine if the inflatable bone tamp (tamp) restores height to compressed vertebral bodies and to compare the biomechanical properties of isolated, fractured osteoporotic vertebral bodies treated by kyphoplasty (tamp) or vertebroplasty. SUMMARY OF BACKGROUND DATA Previous biomechanical stu...
متن کاملEx vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty.
BACKGROUND AND PURPOSE Little is known about the mechanical stabilization afforded by new materials proposed for use with vertebroplasty. This comparative ex vivo biomechanical study was designed to determine the strength and stiffness of osteoporotic vertebral bodies (VBs) subjected to compression fractures and stabilized with bipedicular injections of Cranioplastic altered in a manner consist...
متن کاملBiomechanics of low-modulus and standard acrylic bone cements in simulated vertebroplasty: A human ex vivo study.
The high stiffness of bone cements used in vertebroplasty has been hypothesised to contribute to the propensity of adjacent vertebral fractures after treatment. Therefore, new low-modulus cements have been developed; however, there are currently no studies assessing the biomechanical aspects of vertebroplasty with these cements in an ex vivo non-prophylactic model. In this study, we induced wed...
متن کاملAn ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty.
BACKGROUND AND PURPOSE Previous ex vivo biomechanical studies have shown that kyphoplasty with polymethylmethacrylate cement increases vertebral body (VB) strength and restores VB stiffness and height after compression fracture. The purpose of the current study was to determine if a hydroxyapatite cement used as a void filler during kyphoplasty provides mechanical stabilization similar to that ...
متن کاملBiomechanical Evaluation of Augmentation of Osteoporotic Cancellous Bone with an Injectable Nano-hydroxyapatite/ Polyamide 66 Composite Cement
A new injectable biomimetic composite cement composed of nano-hydroxyapatite (n-HA) and polyamide 66 (polyhexamethylene adipamide) has been developed. This study investigated that in vitro biomechanical performances of three n-HA/PA composite cements in the augmentation of osteoporotic cancellous bone were different in various n-HA content to evaluate the clinical applicability. The thoracic ve...