Technical evaluation of TomoTherapy automatic roll correction

نویسندگان

  • Steve Laub
  • Michael Snyder
  • Jay Burmeister
چکیده

The TomoTherapy Hi·Art System allows the application of rotational corrections as a part of the pretreatment image guidance process. This study outlines a custom method to perform an end-to-end evaluation of the TomoTherapy Hi·Art roll correction feature. A roll-sensitive plan was designed and delivered to a cylindrical solid water phantom to test the accuracy of roll corrections, as well as the ability of the automatic registration feature to detect induced roll. Cylindrical target structures containing coaxial inner avoidance structures were placed adjacent to the plane bisecting the phantom and 7 cm laterally off central axis. The phantom was positioned at isocenter with the target-plane parallel to the couch surface. Varying degrees of phantom roll were induced and dose to the targets and inner avoidance structures was measured using Kodak EDR2 films placed in the target-plane. Normalized point doses were compared with baseline (no roll) data to determine the sensitivity of the test and the effectiveness of the roll correction feature. Gamma analysis comparing baseline, roll-corrected, and uncorrected films was performed using film analysis software. MVCT images were acquired prior to plan delivery. Measured roll was compared with induced roll to evaluate the automatic registration feature's ability to detect rotational misalignment. Rotations beyond 0.3° result in statistically significant deviation from baseline point measurements. Gamma pass rates begin to drop below 90% at approximately 0.5° induced rotation at 3%/3 mm and between 0.2° and 0.3° for 2%/2 mm. With roll correction applied, point dose measurements for all rotations are indistinguishable from baseline, and gamma pass rates exceed 96% when using 3% and 3 mm as evaluation criteria. Measured roll via the automatic registration algorithm agrees with induced rotation to within the test sensitivity for nearly all imaging settings. The TomoTherapy automatic registration system accurately detects induced rotations, and the method presented here for evaluation of the roll correction feature is easily implemented by any clinic with a TomoTherapy Hi·Art unit. This method is sensitive to well within half a degree and demonstrates that the TomoTherapy Hi·Art roll correction feature accurately corrects for induced rotational misalignments to within this level of uncertainty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface imaging, laser positioning or volumetric imaging for breast cancer with nodal involvement treated by helical TomoTherapy

A surface imaging system, Catalyst (C-Rad), was compared with laser-based positioning and daily mega voltage computed tomography (MVCT) setup for breast patients with nodal involvement treated by helical TomoTherapy. Catalyst-based positioning performed better than laser-based positioning. The respective modalities resulted in a standard deviation (SD), 68% confidence interval (CI) of positioni...

متن کامل

Clinical evaluation of the accuracy of an invasive frame designed for stereotactic intracranial radiosurgery treatment with helical tomotherapy.

AIMS AND BACKGROUND The study focused on the evaluation of the accuracy of intracranial stereotactic radiosurgery treatments delivered with helical tomotherapy by means of the InterFix™ Radiosurgery kit. METHODS AND STUDY DESIGN Twenty-two patients received stereotactic radiosurgery treatments with single fraction dose ranging from 13 to 20 Gy depending on diagnosis. Megavoltage computed tomo...

متن کامل

Performance evaluation of the RITG148+ set of TomoTherapy quality assurance tools using RTQA2 radiochromic film

Version 6.3 of the RITG148+ software package offers eight automated analysis routines for quality assurance of the TomoTherapy platform. A performance evaluation of each routine was performed in order to compare RITG148+ results with traditionally accepted analysis techniques and verify that simulated changes in machine parameters are correctly identified by the software. Reference films were e...

متن کامل

A Quantitative Assessment of Imaging Frequency on the Treatment Setup Accuracy in TomoTherapy

Image guided radiation therapy (IGRT) is becoming the standard of practice for many treatment sites and techniques, especially those involving high dose gradients such as stereotactic radiosurgery (SRS), stereotactic radiotherapy (SBRT) and intensity modulated radiotherapy (IMRT). The purpose of this study is to quantify the setup accuracy for various IGRT frequency protocols from tattoo-only s...

متن کامل

Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images

Helical Tomotherapy (HT) has become increasingly popular over the past few years. However, its clinical efficacy and effectiveness continues to be investigated. Pre-treatment patient repositioning in highly conformal image-guided radiation therapy modalities is a prerequisite for reducing setup uncertainties. A MVCT image set has to be acquired to account for daily changes in the patient's inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015