A device for 24 hour ambulatory monitoring of abdominal girth using inductive plethysmography.

نویسندگان

  • B P Reilly
  • M P Bolton
  • M J Lewis
  • L A Houghton
  • P J Whorwell
چکیده

Inductive plethysmography (IP) sensors and oscillator modules were assessed for their potential use in the ambulatory monitoring of abdominal girth in subjects with irritable bowel syndrome (IBS) in order to objectively quantify their bloating symptoms. A dedicated microprocessordata logger was designed to record over 24 h the frequency output of IP oscillators connected to a belt around the subject's lower abdomen. Posture was also recorded via tilt switches (standing, sitting and lying). The system was separately calibrated by placing the belts around a variable rectangular phantom and measuring the frequency of oscillation. A theoretical geometric model was devised to convert measured frequency into circumference and account for changes caused by variations in shape. Using the calibration factors, it was found that the circumference of a circular phantom could be measured accurately (mean difference 1.27 cm and SD 0.25 cm). The system has been tested over 24 h with 20 volunteers. Movement introduced variations in measured girth larger than those found during periods of non-movement during sleep. We conclude that IP promises to be a useful and quantitative tool suitable for ambulatory monitoring of abdominal girth, a hitherto relatively unexplored symptom of IBS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ambulatory abdominal inductance plethysmography: towards objective assessment of abdominal distension in irritable bowel syndrome.

BACKGROUND Abdominal distension is one of the cardinal features of irritable bowel syndrome (IBS) with patients often ranking it as more intrusive than their pain or bowel dysfunction. If this symptom could be quantified accurately and reliably it would provide, for the first time, an objective way of assessing this disorder. Using the principle of inductance plethysmography we have developed a...

متن کامل

Bloating and distention in irritable bowel syndrome: the role of visceral sensation.

BACKGROUND & AIMS Abdominal bloating is an extremely intrusive symptom of irritable bowel syndrome (IBS) that is not always accompanied by an increase in abdominal girth (distention), raising the possibility that these 2 features of the condition may not share a common pathophysiology. A number of mechanisms have been postulated for bloating and distention, but the role of visceral sensation, w...

متن کامل

Real-Time Heart Rate Monitoring System based on Ring-Type Pulse Oximeter Sensor

With the continuous aging of the populations in developed countries, the medical requirements of the aged are expected to increase. In this paper, a ring-type pulse oximeter finger sensor and a 24-hour ambulatory heart rate monitoring system for the aged are presented. We also demonstrate the feasibility of extracting accurate heart rate variability measurements from photoelectric plethysmograp...

متن کامل

Accuracy of ventilatory measurement employing ambulatory inductive plethysmography during tasks of everyday life.

Ambulatory inductive plethysmography (AIP) has recently been introduced to permit monitoring of ventilation outside the clinic and laboratory. It provides a method for nonintrusive assessment of both timing (e.g. respiration rate; RR) and volumetric parameters (e.g. tidal volume and minute ventilation volume; V(T) and V'(E), respectively). Although inductive plethysmography has been validated i...

متن کامل

Detection of Apneas in Infants During Sleep: A Study Comparing Thoracic Impedance and Inductive Plethysmography

Breathing disorders of different etiologies are frequent problems in neonatal intensive care, but also in hospital and outpatient treatment of small infants. Thus, there is a great need for secure and practicable assessment of infants’ respiratory movements and detection of apneas. Current measurement techniques for this purpose include piezo elements, infra red sensors, pneumatic elements, tho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2002