Comparison of left ventricular functional parameters measured by gated single photon emission tomography and by two-dimensional echocardiography.
نویسندگان
چکیده
The aim of the present study was to evaluate the correlation amongst left ventricular (LV) functional parameters estimated by gated single photon emission tomography (GSPET) and two-dimensional (2D) M-mode, echocardiography (ECHOC). GSPET was performed in a single day stress/rest protocol by using either technetium-99m methoxy-isobutyl-isonitrile ((99m)Tc-MIBI) or technetium-99m tetrofosmin ((99m)Tc-myoview) in 36 consecutive patients, 21 males and 15 females; mean age 57.6+/-11.8 y, range 32-82 y. The various LV parameters studied were: ejection fraction (EF), end systolic volume (ESV), end diastolic volume (EDV), stroke volume (SV) and LV mass (LVM). The GSPET data were reconstructed using an automatic algorithm employing filtered back projection (FBP) and further analyzed by Emory cardiac (EC) toolbox versions EO-00369 and EO-00733 for the quantitative determinations of these parameters. All patients underwent ECHOC within 1-2 h of the post-stress data acquisition of GSPET. Our results showed that the LV volumes and the LVM showed good correlation (r=0.749 to 0.952, P=0.01). These values could thus be used interchangeably. The assessment of these parameters by GSPET therefore does not seem to be affected by the dose of the radioactivity administered as the dose of the (99m)Tc-labeled myocardial agents for acquiring rest study was approximately four times higher than that for the stress study. Our results also showed that the mean +/- SD values of the volumes and the EF of the LV evaluated by the two techniques, differed significantly except significant correlations for ESV, EDV and LVEF were observed between the two methods: r=0.574 to 0.954; 0.347 to 0.952 and 0.516 to 0.876 respectively. On the other hand, a wide disagreement was observed in estimating the LVM by the two techniques. The LVM measurements by 2D ECHOC were approximately double the values estimated by GSPET. Despite the large disagreement, a small correlation (r=0.33, P=0.05) was observed for LVM between the two techniques. In conclusion, although we observed a good correlation for LV volumes and LVM between the GSPET and the ECHOC techniques, yet these two techniques cannot be used interchangeably.
منابع مشابه
Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملComparison of left ventricular ejection fraction values obtained using invasive contrast left ventriculography, two-dimensional echocardiography, and gated single-photon emission computed tomography
OBJECTIVES Left ventricular ejection fraction can be measured by a variety of invasive and non-invasive cardiac techniques. This study assesses the relation of three diagnostic modalities to each other in the measurement of left ventricular ejection fraction: invasive contrast left ventriculography, two-dimensional echocardiography, and quantitative gated single-photon emission computed tomogra...
متن کاملDiastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملSingle photon emission computed tomography: An alternative imaging modality in left ventricular evaluation
Various diagnostic imaging modalities have been used for quantitative left ventricular (LV) parameters. Because of the suboptimal value of the most widely used technology, two-dimensional (2D) echocardiography, 3D ultrasonographic imaging has improved accuracy for LV volume and function. Single photon emission computed tomography (SPECT) is another diagnostic method where LV volumetric and func...
متن کاملEvaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy
Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...
متن کاملLeft ventricular systolic/diastolic function evaluated by quantitative ECG-gated SPECT: comparison with echocardiography and plasma BNP analysis.
OBJECTIVE The aim of this study was to evaluate the left ventricular (LV) functional parameters calculated using quantitative electrocardiography (ECG)-gated myocardial perfusion single photon emission computed tomography (QGS). In addition to LV systolic parameters, diastolic parameters were compared with those by ultrasound echocardiography (UCG) and also with plasma B-type natriuretic peptid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hellenic journal of nuclear medicine
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2006