Silicon measurement in serum and urine by direct current plasma emission spectrometry.
نویسندگان
چکیده
Elemental silicon, present as soluble silicic acid in serum and urine, has been measured by direct current plasma emission spectrometry. The method is precise and accurate, yields a standard curve that is linear up to 1000 mumol/L, and requires only a simple dilution in 10 mL/L HNO3. No spectral or background interferences have been observed from serum or urine; the absolute detection limit for silicon was 0.5 mumol/L. Silicon concentrations in serum increase by up to 20-fold in patients with chronic renal failure on hemodialysis, an increase apparently related to dietary silicon intake. No relationship with aluminum was observed in hemodialysis patients, with or without aluminum toxicity. In the undialyzed patient with chronic renal failure, the concentrations of silicon in plasma increased with decreasing glomerular filtration rate. This increase may protect renal-failure patients from possible aluminum toxicity by promoting formation of the relatively inactive aluminosilicate complex. Silicon concentrations in urine of healthy individuals exceed their serum concentrations by 20- to 100-fold. Silicon excretion in patients with renal stones was not different from that in healthy controls and showed no relationship with calcium and (or) oxalate excretion.
منابع مشابه
Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression
A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...
متن کاملThe silicon supplement ‘Monomethylsilanetriol’ is safe and increases the body pool of silicon in healthy Pre-menopausal women
BACKGROUND Monomethylsilanetriol (MMST) has been used for decades as an oral silicon supplement for bone and connective tissue health, although there are no formal data on its in vivo utilisation or safety following sustained dosing. METHODS To investigate whether MMST contributes to the body pool of silicon and, secondly, to establish its safety following 4 weeks' supplementation in humans, ...
متن کاملElimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملSelective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
متن کاملRoutine measurement of calcium, magnesium, copper, zinc, and iron in urine and serum by inductively coupled plasma emission spectroscopy.
We describe an inductively coupled plasma atomic emission spectrometer that has been adapted to perform routine, simultaneous, direct analyses of calcium, magnesium, copper, zinc, and iron in serum or urine without sample digestion or pretreatment. The system, constructed with inexpensive, readily available components, can analyze 1-mL or smaller samples. Results correlate nearly perfectly with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 36 8 Pt 1 شماره
صفحات -
تاریخ انتشار 1990