Automated line scan analysis to quantify biosensor activity at the cell edge.
نویسندگان
چکیده
Biosensors are valuable tools used to image the subcellular localization and kinetics of protein activity in living cells. Signaling at the edge of motile cells that regulates cell protrusion and retraction is important in many aspects of cell physiology, and frequently studied using biosensors. However, quantitation and interpretation is limited by the heterogeneity of this signaling behavior; automated analytical approaches are required to systematically extract large data sets from biosensor studies for statistical analysis. Here we describe an automated analysis to relate the velocity at specific points along the cell edge with biosensor activity in adjoining regions. Time series of biosensor images are processed to interpolate a smooth edge of the cell at each time point. Profiles of biosensor activity ('line scans') are then calculated along lines perpendicular to the cell edge. An energy minimization method is used to calculate a velocity associated with each line scan. Sorting line scans by the proximal velocity has generated novel biological insights, as exemplified by analysis of the Src merobody biosensor. With the large data sets that can be generated automatically by this program, conclusions can be drawn that are not apparent from qualitative or 'manual' quantitative techniques. Our 'LineScan' software includes a graphical user interface (GUI) to facilitate application in other studies. It is available at hahnlab.com and is exemplified here in a study using the RhoC FLARE biosensor.
منابع مشابه
Design and application of a bioluminescent biosensor for detection of toxicity using Huh7-CMV-luc cell line
Cell-based biosensors (CBBs) are becoming important tools for biosecurity applications and rapid diagnostics in food microbiology for their unique capability of detecting hazardous materials. Pollutants, such as heavy metals and chemicals, are now considered as a global threat and are associated with detrimental health outcomes. Fast and accurate detection of pollutants is essential to reduce t...
متن کاملDesign and application of a bioluminescent biosensor for detection of toxicity using Huh7-CMV-luc cell line
Cell-based biosensors (CBBs) are becoming important tools for biosecurity applications and rapid diagnostics in food microbiology for their unique capability of detecting hazardous materials. Pollutants, such as heavy metals and chemicals, are now considered as a global threat and are associated with detrimental health outcomes. Fast and accurate detection of pollutants is essential to reduce t...
متن کاملEffect of Passage Number and Culture Time on the Expression and Activity of Insulin-Degrading Enzyme in Caco-2 Cells
Background: Insulin-degrading enzyme (IDE) is a conserved zinc metallopeptidase. Here, we have evaluated the effect of passage number and culture time on IDE expression and activity in colorectal adenocarcinoma cell line (Caco-2). Methods: Caco-2 cells were cultured with different passage ranges of 5-15, 25-35, 52-63 for 48, 72, and 120 hours. Subsequently, IDE expression and enzyme activity we...
متن کاملA biosensor generated via high throughput screening quantifies cell edge Src dynamics
Fluorescent biosensors for living cells currently require laborious optimization and a unique design for each target. They are limited by the availability of naturally occurring ligands with appropriate target specificity. Here we describe a biosensor based on an engineered fibronectin monobody scaffold that can be tailored to bind different targets via high-throughput screening. We made this S...
متن کاملA Human Inspired Local Ratio-Based Algorithm for Edge Detection in Fluorescent Cell Images
We have developed a new semi-automated method for segmenting images of biological cells seeded at low density on tissue culture substrates, which we use to improve the generation of reference data for the evaluation of automated segmentation algorithms. The method was designed to mimic manual cell segmentation and is based on a model of human visual perception. We demonstrate a need for automat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Methods
دوره 66 2 شماره
صفحات -
تاریخ انتشار 2014